Harnessing feature extraction capacities from a pre-trained convolutional neural network (VGG-16) for the unsupervised distinction of aortic outflow velocity profiles in patients with severe aortic stenosis

Author:

Lachmann Mark1ORCID,Rippen Elena1ORCID,Rueckert Daniel23ORCID,Schuster Tibor4,Xhepa Erion56ORCID,von Scheidt Moritz56ORCID,Pellegrini Costanza5,Trenkwalder Teresa5ORCID,Rheude Tobias5,Stundl Anja1ORCID,Thalmann Ruth1,Harmsen Gerhard7,Yuasa Shinsuke8,Schunkert Heribert56ORCID,Kastrati Adnan56ORCID,Joner Michael56,Kupatt Christian16ORCID,Laugwitz Karl Ludwig16ORCID

Affiliation:

1. First Department of Medicine, Klinikum rechts der Isar, Technical University of Munich , Ismaninger Straße 22 , 81675 Munich, Germany

2. Institute for AI and Informatics in Medicine, Faculty of Informatics and Medicine, Klinikum rechts der Isar, Technical University of Munich , Munich , Germany

3. Department of Computing, Imperial College London , London , UK

4. Department of Family Medicine, McGill University , Montreal, Quebec , Canada

5. Department of Cardiology, German Heart Centre Munich, Technical University of Munich , Munich , Germany

6. DZHK (German Centre for Cardiovascular Research), partner site Munich Heart Alliance , Munich , Germany

7. Department of Physics, University of Johannesburg , Auckland Park , South Africa

8. Department of Cardiology, Keio University School of Medicine , Minato, Tokyo , Japan

Abstract

Abstract Aims Hypothesizing that aortic outflow velocity profiles contain more valuable information about aortic valve obstruction and left ventricular contractility than can be captured by the human eye, features of the complex geometry of Doppler tracings from patients with severe aortic stenosis (AS) were extracted by a convolutional neural network (CNN). Methods and results After pre-training a CNN (VGG-16) on a large data set (ImageNet data set; 14 million images belonging to 1000 classes), the convolutional part was employed to transform Doppler tracings to 1D arrays. Among 366 eligible patients [age: 79.8 ± 6.77 years; 146 (39.9%) women] with pre-procedural echocardiography and right heart catheterization prior to transcatheter aortic valve replacement (TAVR), good quality Doppler tracings from 101 patients were analysed. The convolutional part of the pre-trained VGG-16 model in conjunction with principal component analysis and k-means clustering distinguished two shapes of aortic outflow velocity profiles. Kaplan–Meier analysis revealed that mortality in patients from Cluster 2 (n = 40, 39.6%) was significantly increased [hazard ratio (HR) for 2-year mortality: 3; 95% confidence interval (CI): 1–8.9]. Apart from reduced cardiac output and mean aortic valve gradient, patients from Cluster 2 were also characterized by signs of pulmonary hypertension, impaired right ventricular function, and right atrial enlargement. After training an extreme gradient boosting algorithm on these 101 patients, validation on the remaining 265 patients confirmed that patients assigned to Cluster 2 show increased mortality (HR for 2-year mortality: 2.6; 95% CI: 1.4–5.1, P-value: 0.004). Conclusion Transfer learning enables sophisticated pattern recognition even in clinical data sets of limited size. Importantly, it is the left ventricular compensation capacity in the face of increased afterload, and not so much the actual obstruction of the aortic valve, that determines fate after TAVR.

Funder

Technical University of Munich

Else Kröner-Fresenius Foundation

Publisher

Oxford University Press (OUP)

Subject

Energy Engineering and Power Technology,Fuel Technology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3