An explainable artificial intelligence-enabled electrocardiogram analysis model for the classification of reduced left ventricular function

Author:

Katsushika Susumu1ORCID,Kodera Satoshi1,Sawano Shinnosuke1,Shinohara Hiroki1,Setoguchi Naoto2,Tanabe Kengo2,Higashikuni Yasutomi1,Takeda Norifumi1,Fujiu Katsuhito3,Daimon Masao4ORCID,Akazawa Hiroshi1,Morita Hiroyuki1,Komuro Issei1ORCID

Affiliation:

1. Department of Cardiovascular Medicine, The University of Tokyo Hospital , 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 , Japan

2. Department of Cardiovascular Medicine, Mitsui Memorial Hospital , 1 Kanda-Izumi-cho, Chiyoda-ku, Tokyo 101-8643 , Japan

3. Department of Advanced Cardiology, The University of Tokyo , 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 , Japan

4. Department of Clinical Laboratory, The University of Tokyo Hospital , 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 , Japan

Abstract

Abstract Aims The black box nature of artificial intelligence (AI) hinders the development of interpretable AI models that are applicable in clinical practice. We aimed to develop an AI model for classifying patients of reduced left ventricular ejection fraction (LVEF) from 12-lead electrocardiograms (ECG) with the decision-interpretability. Methods and results We acquired paired ECG and echocardiography datasets from the central and co-operative institutions. For the central institution dataset, a random forest model was trained to identify patients with reduced LVEF among 29 907 ECGs. Shapley additive explanations were applied to 7196 ECGs. To extract the model’s decision criteria, the calculated Shapley additive explanations values were clustered for 192 non-paced rhythm patients in which reduced LVEF was predicted. Although the extracted criteria were different for each cluster, these criteria generally comprised a combination of six ECG findings: negative T-wave inversion in I/V5–6 leads, low voltage in I/II/V4–6 leads, Q wave in V3–6 leads, ventricular activation time prolongation in I/V5–6 leads, S-wave prolongation in V2–3 leads, and corrected QT interval prolongation. Similarly, for the co-operative institution dataset, the extracted criteria comprised a combination of the same six ECG findings. Furthermore, the accuracy of seven cardiologists’ ECG readings improved significantly after watching a video explaining the interpretation of these criteria (before, 62.9% ± 3.9% vs. after, 73.9% ± 2.4%; P = 0.02). Conclusion We visually interpreted the model’s decision criteria to evaluate its validity, thereby developing a model that provided the decision-interpretability required for clinical application.

Funder

Japan Agency for Medical Research and Development

Publisher

Oxford University Press (OUP)

Subject

Energy Engineering and Power Technology,Fuel Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3