Utility of wearable physical activity monitors in cardiovascular disease: a systematic review of 11 464 patients and recommendations for optimal use

Author:

Hammond-Haley Matthew12,Allen Christopher12,Han Jennie3,Patterson Tiffany12,Marber Michael12,Redwood Simon12ORCID

Affiliation:

1. British Heart Foundation Centre of Research Excellence, King's College London, Rayne Institute, St Thomas' Hospital, Westminster Bridge Road, London, SE1 7EP, UK

2. Department of Cardiology, Guys’ and St Thomas NHS Foundation Trust, St Thomas' Hospital, Westminster Bridge Road, London, UK

3. Royal Lancaster Infirmary, Ashton Road Lancaster, LA1 4RP, UK

Abstract

Abstract Aims Physical activity (PA) plays an important role in primary and secondary prevention of cardiovascular disease (CVD), functioning as a marker of disease progression and response to therapy. Real-world measurement of habitual PA is now possible through wearable activity monitors, however, their use in cardiovascular patients is not well described. Methods and results We performed a systematic review to summarize how wearable activity monitors have been used to measure PA in patients with CVD, with 11 464 patients included across 108 studies. Activity monitors were primarily used in the setting of cardiac rehabilitation (46, 43%). Most often, triaxial accelerometers (70, 65%) were instructed to be worn at the hip (58, 54%) for 7 days (n = 54, 50%). Thirty-nine different activity monitors were used, with a range of accelerometer specific settings for collection and reporting of activity data. Activity was reported most commonly as time spent in metabolic equivalent-defined activity levels (49, 45%), while non-wear time was defined in just 16 (15%) studies. Conclusion The collecting, processing, and reporting of accelerometer-related outcomes were highly heterogeneous. Most validation studies are limited to healthy young adults, while the paucity of methodological information disclosed renders interpretation of results and cross-study comparison challenging. While accelerometers are promising tools to measure real-world PA, we highlight current challenges facing their use in elderly multimorbid cardiology patients. We suggest recommendations to guide investigators using these devices in cardiovascular research. Future work is required to determine optimal methodology and consensus-based development of meaningful outcomes using raw acceleration data.

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司