Radiation eye dose to medical staff during respiratory endoscopy under X-ray fluoroscopy

Author:

Haga Yoshihiro12,Chida Koichi13,Kimura Yuichiro4,Yamanda Shinsuke4,Sota Masahiro12,Abe Mitsuya2,Kaga Yuji2,Meguro Taiichiro5,Zuguchi Masayuki1

Affiliation:

1. Department of Radiological Technology, Tohoku University Graduate School of Medicine, 2-1 Seiryo, Aoba, Sendai 980-8575, Japan

2. Department of Radiology, Sendai Kousei Hospital, Sendai, Miyagi, Japan, Hirosemachi 4-15, Aobaku, Sendai 980-0873, Japan

3. Division of Disaster Medicine, International Research Institute of Disaster Science, Tohoku University, 6-6-4, Aoba, Sendai 980-8579, Japan

4. Department of Respiratory Medicine, Sendai Kousei Hospital, Sendai, Miyagi, Japan, Hirosemachi 4-15, Aobaku, Sendai 980-0873, Japan

5. Department of Cardiovascular Medicine, Sendai Kousei Hospital, Sendai, Miyagi, Japan, Hirosemachi 4-15, Aobaku, Sendai 980-0873, Japan

Abstract

Abstract Although the clinical value of fluoroscopically guided respiratory endoscopy (bronchoscopy) is clear, there have been very few studies on the radiation dose received by staff during fluoroscopically guided bronchoscopy. The International Commission on Radiological Protection (ICRP) is suggesting reducing the occupational lens dose limit markedly from 150 to 20 mSv/year, averaged over defined periods of five years. The purpose of this study was to clarify the current occupational eye dose of bronchoscopy staff conducting fluoroscopically guided procedures. We measured the occupational eye doses (3-mm-dose equivalent, Hp(3)) of bronchoscopy staff (physicians and nurses) over a 6-month period. The eye doses of eight physicians and three nurses were recorded using a direct eye dosimeter, the DOSIRIS. We also estimated eye doses using personal dosimeters worn at the neck. The mean ± SD radiation eye doses (DOSIRIS) to physicians and nurses were 7.68 ± 5.27 and 2.41 ± 1.94 mSv/6 months, respectively. The new lens dose limit, 20 mSv/year, may be exceeded among bronchoscopy staff, especially physicians. The eye dose of bronchoscopy staff (both physicians and nurses) was underestimated when measured using a neck dosimeter. Hence, the occupational eye dose of bronchoscopy staff should be monitored. To reduce the occupational eye dose, we recommend that staff performing fluoroscopically guided bronchoscopy wear Pb glasses. correct evaluation of the lens dose [Hp(3)] using an eye dosimeter such as the DOSIRIS is necessary for bronchoscopy staff.

Funder

Industrial Disease Clinical Research

Radiation Safety Research Promotion Fund

Nuclear Regulation Authority

Publisher

Oxford University Press (OUP)

Subject

Health, Toxicology and Mutagenesis,Radiology, Nuclear Medicine and imaging,Radiation

Reference33 articles.

1. British Thoracic Society guideline for diagnostic flexible bronchoscopy in adults: Accredited by NICE;Du Rand;Thorax,2013

2. Bronchoscopic techniques in diagnosis and staging of lung cancer;Herth;Breathe,2011

3. A survey of flexible bronchoscopy practices in India: The Indian bronchoscopy survey (2017);Madan;Lung India.,2018 -

4. Bronchoscopic practice in Japan: A survey by the Japan Society for Respiratory Endoscopy in 2010;Asano;Respirology,2013

5. Cross-sectional survey on bronchoscopy in Germany – The current status of clinical practice;Hautmann;Pneumologie,2016