Internal exposure rate conversion coefficients and absorbed fractions of mouse for 137Cs, 134Cs and 90Sr contamination in body

Author:

Endo Satoru1,Matsutani Yuki1,Kajimoto Tsuyoshi1,Tanaka Kenichi1,Suzuki Masatoshi2

Affiliation:

1. Quantum Energy Applications, Graduate School of Advanced Science and Engineering, Hiroshima University, 1-4-1 Kagamiyama, Higashi-Hiroshima 739-8527, Japan

2. International Research Institute of Disaster Science (IRIDeS), Tohoku University, Aramaki Aza-Aoba 468-1, Aoba-ku, Sendai 980-8572, Japan

Abstract

Abstract The aim of this study was to determine parameters for estimating the internal exposure of all organs in mouse experiments from the radioactivity concentration in organs. The estimation of internal exposure rate conversion coefficients and absorbed fractions for 137Cs, 134Cs and 90Sr by the Particle and Heavy Ion Transport code System (PHITS) with a voxel-based mouse phantom is presented. The geometry of the voxel phantom is constructed from computer tomography images of a mouse 9 cm in length weighing 23.9 g. The voxel-based mouse phantom has the following organs: brain, skull, heart, lungs, liver, stomach, spleen, kidneys, bladder, testis and tissue (tissue and other organs). Gamma- and beta-rays from 137Cs, 134Cs and 90Sr sources in each source organ are generated and scored for every target organ. The internal exposure rate conversion coefficients and absorbed fractions are calculated from deposition energies in each target organ from each source organ and are used to generate an internal exposure rate conversion coefficient matrix and an absorbed fraction matrix. The absorbed fractions of beta-rays in the source organs are roughly 0.5–0.8 for 137Cs and 134Cs, and the absorbed fractions of gamma-rays are <0.04 for 137Cs and <0.03 for 134Cs. The internal exposure rate conversion coefficient matrix is defined using the absorbed fractions. The calculated internal exposure rate coefficient matrix is tested under a uniform radioactivity concentration of 1 Bq/kg for 137Cs, 134Cs and 90Sr. The estimated internal exposure rates in the mouse whole body for 137Cs, 134Cs and 90Sr are 3.28 × 10−3, 2.55 × 10−3 and 1.20 × 10−2 μGy/d, respectively. These values are very similar to those for an ellipsoid frog (31.4 g) and an ellipsoid crab egg mass (12.6 g) reported in ICRP Publication 108.

Funder

JAEA Nuclear Energy S&T and Human Resource Development

Publisher

Oxford University Press (OUP)

Subject

Health, Toxicology and Mutagenesis,Radiology, Nuclear Medicine and imaging,Radiation

Reference20 articles.

1. A comprehensive dose evaluation project concerning animals affected by the Fukushima Daiichi nuclear power plant accident: Its set-up and progress;Takahashi;Journal of Radiation Research,2015

2. The causal relationship between DNA damage induction in bovine lymphocytes and the Fukushima nuclear power plant accident;Nakamura;Radiat Res,2017

3. Analysis of plasma protein concentrations and enzyme activities in cattle within the ex-evacuation zone of the Fukushima Daiichi nuclear plant accident;Urushihara;PLoS One,2016

4. Haematological analysis of Japanese macaques (Macaca fuscata) in the area affected by the Fukushima Daiichi nuclear power plant accident;Urushihara;Scientific Reportsvolume 8,2018

5. Chromosomal aberrations in large Japanese field mice (Apodemus speciosus) captured near Fukushima Dai-ichi nuclear power plant;Kawagoshi;Environ. Sci. Technol.,2017

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3