Comparison of prostate verification with implanted gold markers in tissue surrounding the prostate and pelvic bony anatomy for external beam radiation therapy following low-dose-rate brachytherapy: a prospective clinical trial

Author:

Kaneda Tomoya12,Ohashi Toshio12,Hanada Takashi1,Takenaka Koji2,Nishimura Shuichi1,Sakayori Masanori12,Sutani Shinya1,Momma Tetsuo3,Shigematsu Naoyuki1

Affiliation:

1. Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan

2. Department of Radiology, National Hospital Organization Saitama Hospital, 2-1 Suwa, Wako, Saitama 351-0102, Japan

3. Department of Urology, National Hospital Organization Saitama Hospital, 2-1 Suwa, Wako, Saitama 351-0102, Japan

Abstract

Abstract We aimed to investigate whether gold marker implantation in the tissue surrounding the prostate could accurately monitor setup errors during external beam radiation therapy (EBRT) following low-dose-rate (LDR) brachytherapy. Thirty-eight patients had confirmed intermediate- or high-risk prostate cancer and received EBRT following LDR brachytherapy. In >175 computed tomography imaging sessions, the average values of the weekly setup error during EBRT to the prostate centroid at the time of gold marker matching in the surrounding tissue of the prostate and pelvic bone matching were measured and then compared using the Wilcoxon signed-rank test. Gold marker matching in the surrounding tissue of the prostate estimated setup errors better than those estimated by bone matching (3D displacement = 2.7 ± 2.0 vs 3.8 ± 2.6 mm, P < 0.01). Overall, the standard deviation of systematic (Σ) and random (σ) setup error was lower with gold marker matching than with bone matching (3D displacement = 1.8 and 1.1 mm vs 2.1 and 1.6 mm, respectively). With gold marker matching, the setup error of the position of the prostate centroid was smaller, and the optimal setup margin was lower than that with bone matching (2Σ + 0.7σ and 2.5Σ + 0.7σ of 3D displacement = 4.3 and 5.2 mm vs 5.3 and 6.4 mm, respectively). This high-precision radiotherapy approach placing gold markers in the surrounding tissue of the prostate can allow more accurate setup during EBRT following LDR brachytherapy.

Funder

JSPS

Publisher

Oxford University Press (OUP)

Subject

Health, Toxicology and Mutagenesis,Radiology, Nuclear Medicine and imaging,Radiation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3