Ascending aorta replacement in patients with coronary ostia localized above the sinotubular junction

Author:

Urbanski Paul P1ORCID,Irimie Vadim1,Diegeler Anno1,Morka Aleksandra2,Thamm Tarvo3,Lehmkuhl Lukas4

Affiliation:

1. Department of Cardiovascular Surgery, Cardiovascular Clinic Bad Neustadt, Bad Neustadt, Germany

2. Department of Cardiac Surgery and Cardiosurgical Intensive Care, Children’s University Hospital, Jagiellonian University Medical College, Krakow, Poland

3. Department for Medical Statistics, Campus Bad Neustadt, Bad Neustadt, Germany

4. Department of Radiology, Cardiovascular Clinic Bad Neustadt, Bad Neustadt, Germany

Abstract

Abstract OBJECTIVES The study objective was to describe the technique and outcomes of original coronary ostial slide plasty in patients with anomalous coronary artery origin (ACAO) localized in the aneurysmal ascending aorta (AA) being replaced because of its isolated pathology and otherwise non-pathological aortic root. METHODS A total of 23 patients (median age 52 years) with the ascending phenotype of proximal aorta aneurysm and ACAO of at least 1 coronary artery localized in the AA being replaced underwent ostial slide plasty to transpose the ACAO to the respective sinus of Valsalva and, consequently, to allow an AA replacement with placement of the proximal anastomosis at the level of the sinotubular junction (STJ). In 15 patients, the aortic valve was bicuspid, and all but 3 patients presented with a relevant valve defect. In addition to remodelling the STJs (all patients), valve-sparing repair or replacement was performed in 12 and 8 patients, respectively. RESULTS No patient died during the entire follow-up (median 72, range 3–183 months). One patient required replacement of a recurrently insufficient valve that was repaired primarily using cusp patch plasty, but there were no further cardiac reoperations nor any re-interventions on the proximal aorta, aortic valve and/or coronary artery ostia. Two patients received peripheral coronary stents (8 and 7 years after surgery, respectively) due to coronary heart disease. CONCLUSIONS Transposition of the ACAO from the replaced AA into the normal sinus of Valsalva using the ostial slide plasty offers a simple and safe surgical option enabling a recreation of a durable STJ at the level of the anastomosis between the root and the aortic graft.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

Reference15 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3