Determination of selective antegrade perfusion flow rate in aortic arch surgery to restore baseline cerebral near-infrared spectroscopy values: a single-centre observational study

Author:

Friess Jan-Oliver12ORCID,Beeler Maurus1,Yildiz Murat3,Guensch Dominik P1,Levis Anja1,Gerber Daniel1,Wollborn Jakob4,Jenni Hansjoerg3,Huber Markus1,Schönhoff Florian3,Erdoes Gabor1ORCID

Affiliation:

1. Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern , Bern, Switzerland

2. Department of Anesthesiology, Critical Care and Pain Medicine, Boston Children's Hospital, Harvard Medical School , Boston, USA

3. Department of Cardiac Surgery, Inselspital, Bern University Hospital, University of Bern , Bern, Switzerland

4. Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital, Harvard Medical School , Boston, USA

Abstract

Abstract OBJECTIVES Neuroprotection during aortic arch surgery involves selective antegrade cerebral perfusion. The parameters of cerebral perfusion, e.g. flow rate, are inconsistent across centres and are subject of debate. The aim of this study was to determine the cerebral perfusion flow rate during hypothermic circulatory arrest required to meet preoperative awake baseline regional cerebral oxygen saturation (rSO2). METHODS Patients scheduled for aortic arch surgery with hypothermic circulatory arrest were enrolled in this prospective observational study. After initiation of hypothermic circulatory arrest, bilateral selective antegrade cerebral perfusion was established and cerebral flow rate was continuously increased. The primary end point was the difference of cerebral saturation from baseline during cerebral perfusion flow rates of 6, 8 and 10 ml/kg/min. RESULTS A total of 40 patients were included. During antegrade cerebral perfusion, rSO2 was significantly lower than the baseline at 6 ml/kg/min [−7.3, 95% confidence interval (CI): −1.7, −12.9; P = 0.0015]. In contrast, flow rates of 8 and 10 ml/kg/min resulted in rSO2 that did not significantly differ from the baseline (−2; 95% CI: −4.3, 8.3; P > 0.99 and 1.8; 95% CI: −8.5%, 4.8%; P > 0.99). Cerebral saturation was significantly more likely to meet baseline values during selective antegrade cerebral perfusion with 8 ml/kg/min than at 6 ml/kg/min (44.1%; 95% CI: 27.4%, 60.8% vs 11.8%; 95% CI: 0.9%, 22.6%; P = 0.0001). CONCLUSIONS At 8 ml/kg/min cerebral flow rate during selective antegrade cerebral perfusion, regional cerebral oximetry baseline values are significantly more likely to be achieved than at 6 ml/kg/min. Further increasing the cerebral flow rate to 10 ml/kg/min does not significantly improve rSO2.

Funder

Bern University Hospital

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3