Stent deformation in a sutureless aortic valve bioprosthesis: a pilot observational analysis using imaging and three-dimensional modelling

Author:

Aljalloud Ali12,Spetsotaki Konstantina1,Tewarie Lachmandath1,Rossato Leonardo3ORCID,Steinseifer Ulrich3,Autschbach Ruediger1,Menne Matthias3ORCID

Affiliation:

1. Department of Thoracic and Cardiovascular Surgery, RWTH University Hospital Aachen, Aachen, Germany

2. Department of Cardiology, Rhein Maas Klinikum, Würselen, Germany

3. Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany

Abstract

Abstract OBJECTIVES The goal of this analysis of the Perceval aortic bioprosthesis was to investigate the ovalization/deformation of the Perceval prosthesis stent after implantation and its propensity for cusp dysfunction, fluttering, fibrosis and blockage. METHODS Between August 2014 and May 2019, a total of 134 patients (52% female) underwent aortic valve replacement with the Perceval bioprosthesis. We reconstructed three-dimensional models of the Perceval stent using thorax computed tomography scans for 16 patients employing the software Mimics (Materialise NV, Leuven, Belgium) and analysed the ovality of the stents. Radial force (RF) measurements were performed to compare the stiffness of the Perceval bioprosthesis to that of other valves. RESULTS The three-dimensional reconstructions showed that all Perceval stents exhibited some degree of deformation and ovalization. Ovality in the annulus and commissure section of the Perceval stents ranged from 6.8% to 45% with mean values of 13.6% and 21.9%, respectively. The RF of the Perceval prosthesis was noticeably lower than that of the Edwards Intuity and several transcatheter aortic valve implantation devices. The stent adopted the preoperative shape of the aorta in the 2 patients for whom pre- and postoperative computed tomography data existed. CONCLUSIONS The Perceval bioprostheses were deformed to different degrees in all analysed cases. The comparably low RFs might be an explanation for the propensity towards this deformation, which can lead to fluttering, a reduction of the cusps’ mobility. This condition could potentially result in fibrosis as well as increased transvalvular pressure gradients and might be the cause for the increase in lactate dehydrogenase and the decrease in platelet count.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3