Patency of separate tube grafts for intercostal artery reconstruction: Size and length matter

Author:

Shiiya Norihiko1ORCID,Washiyama Naoki1ORCID,Takahashi Daisuke1,Tsuda Kazumasa1,Ohashi Yuko1,Natsume Kayoko1,Hirano Masahiro1,Takeuchi Yuki1

Affiliation:

1. First Department of Surgery, Hamamatsu University School of Medicine , Hamamatsu, Japan

Abstract

Abstract OBJECTIVES Low patency is a major concern when using separate tube grafts for intercostal artery reconstruction. Our goal was to elucidate the optimal size and length of grafts from their patency and the computational fluid dynamics (CFD). METHODS The patency, size and length of separate tube grafts were evaluated in 41 patients. Simulation of CFD was performed in a model derived from a patient with a patent 12-mm graft that was 15 mm long, with 2 simulation models with a smaller (8-mm) or longer (30-mm) graft. RESULTS A total of 49 grafts were used for intercostal artery reconstruction. There was 1 in-hospital death and 2 spinal cord injuries. The patency rate, which could be evaluated in 46 grafts, was 63% (29/46). It was 71% (24/34) in thoracoabdominal aortic replacement and 42% (5/12) in descending aortic replacement. Among 14 patients in whom all grafts were occluded, no patients developed spinal cord injury. All grafts longer than 25 mm were occluded (n = 5). Eight- and 10-mm grafts showed better patency than 12-mm grafts in thoracoabdominal aortic replacement (P = 0.008) when grafts were shorter than 25 mm. Simulation of CFD revealed vortical flow within the 12-mm graft, which did not reach the intercostal orifice, whereas helical flow was maintained throughout the cardiac cycle within the 8-mm graft. CONCLUSIONS Eight- and 10-mm grafts seemed better than 12-mm grafts, and grafts should be kept shorter than 25 mm. Simulation of CFD may shed light on the issue of the optimal intercostal artery reconstruction technique.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

Reference14 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3