Clinical feasibility and safety of transoesophageal motor-evoked potential monitoring

Author:

Shiiya Norihiko1ORCID,Tsuda Kazumasa1ORCID,Yamanaka Ken1,Takahashi Daisuke1,Washiyama Naoki1,Yamashita Katsushi1,Kando Yumi1,Ohashi Yuko1

Affiliation:

1. First Department of Surgery, Hamamatsu University School of Medicine, Hamamatsu, Japan

Abstract

Abstract OBJECTIVES Canine experiments have shown that transoesophageal motor-evoked potential monitoring is feasible, safe and stable, with a quicker response to ischaemia and a better prognostic value than transcranial motor-evoked potentials. We aimed to elucidate whether or not these findings were clinically reproducible. METHODS A bipolar oesophageal electrode mounted on a large-diameter silicon tube and a train of 5 biphasic wave stimuli were used for transoesophageal stimulation. Results of 18 patients (median age 74.5 years, 13 males) were analysed. RESULTS There were no mortalities, spinal cord injuries or complications related with transoesophageal stimulation. Transcranial motor-evoked potential could not be monitored up to the end of surgery in 3 patients for unknown reasons, 2 of whom from the beginning. Transoesophageal motor-evoked potential became non-evocable after manipulation of a transoesophageal echo probe in 2 patients. Strenuous movement of the upper limbs during transoesophageal stimulation was observed in 3 patients. In 14 patients who successfully completed both monitoring methods up to the end of surgery (11 thoraco-abdominal and 3 descending aortic repair), the final results were judged as false positives in 6 by transcranial stimulation and in 1 by transoesophageal stimulation. The stimulation intensity was significantly lower and the upper limb amplitude was significantly higher by transoesophageal stimulation, while the lower limb amplitude was comparable. CONCLUSIONS Transoesophageal motor-evoked potential monitoring is clinically feasible and safe with a low false positive rate. A better electrode design is required to avoid its migration by transoesophageal echo manipulation. Further studies may be warranted. Clinical registration number UMIN000022320.

Funder

Japanese Ministry of Education, Culture, Sports, Science and Technology

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3