Early and mid-term outcomes after aortic valve replacement using a novel tissue bioprosthesis: a systematic review

Author:

Sef Davorin1ORCID,Thet Myat Soe2ORCID,Klokocovnik Tomislav3ORCID,Luthra Suvitesh4

Affiliation:

1. University Hospitals of Leicester Department of Cardiac Surgery, , Leicester, UK

2. Faculty of Medicine, Department of Surgery and Cancer, Imperial College London & Imperial College Healthcare NHS Trust , London, UK

3. Department of Cardiac Surgery, General Hospital Celje , Celje, Slovenia

4. Department of Cardiac Surgery, Wessex Cardiothoracic Centre, University Hospital of Southampton, Southampton, UK

Abstract

Abstract OBJECTIVES While current data show a clear trend towards the use of bioprosthetic valves during aortic valve replacement (AVR), durability of bioprosthetic valves remains the most important concern. We conducted a 1st systematic review of all available evidence that analysed early and mid-term outcomes after AVR using the Inspiris RESILIA™ bioprosthesis. METHODS A systematic literature search was performed to identify all relevant studies evaluating early and mid-term outcomes after AVR using the Inspiris RESILIA bioprosthesis and including at least 20 patients with no restriction on the publication date. Subgroup meta-analysis was performed to compare Inspiris RESILIA and PERIMOUNT Magna Ease bioprosthesis and to pool the early postoperative mortality and stroke rates. RESULTS A total of 416 studies were identified, of which 15 studies met the eligibility criteria. The studies included a total of 3202 patients with an average follow-up of up to 5.3 years. The average age of patients across the studies was 52.2–75.1 years. Isolated AVR was performed in 39.0–86.4% of patients. In-hospital or 30-day postoperative mortality was 0–2.8%. At the mid-term follow-up, freedom from all-cause mortality was up to 85.4%. Among studies with mid-term follow-up, trace/mild paravalvular leak was detected in 0–3.0%, while major paravalvular leak was found only in up to 2.0% of patients. No statistically significant differences in terms of mortality (P = 0.98, odds ratio 1.02, 95% confidence interval 0.36–2.83) and stroke (P = 0.98, odds ratio 1.01, 95% confidence interval 0.38–2.73) between the Inspiris RESILIA bioprosthesis and PERIMOUNT Magna Ease bioprosthesis were observed in the subgroup meta-analysis. CONCLUSIONS Mid-term data on the safety and haemodynamic performance of the novel aortic bioprosthesis are encouraging. Further comparative studies with other bioprostheses and longer follow-up are still required to endorse durability and safety of the novel bioprosthesis.

Publisher

Oxford University Press (OUP)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献