Acquired von Willebrand factor deficiency is reduced in HeartMate 3 patients†

Author:

Klaeske Kristin1,Dieterlen Maja-Theresa1,Scholz Ute2,Lehmann Sven1,Garbade Jens1,Fischer Julia1,Jawad Khalil1,Borger Michael A1,Meyer Anna1

Affiliation:

1. Department of Cardiac Surgery, University of Leipzig, Heart Center Leipzig, Helios Clinic, Leipzig, Germany

2. Zentrum für Blutgerinnungsstörungen, MVZ Labor Dr. Reising-Ackermann und Kollegen, Leipzig, Germany

Abstract

Abstract OBJECTIVES The acquired von Willebrand syndrome (AvWS), which is associated with left ventricular assist device support, is caused by the loss of the von Willebrand factor (vWF) high molecular weight multimers (HMWMs). We investigated whether the implantation of the left ventricular assist device HeartMate 3 (HM 3) is superior to the HeartWare ventricular assist device (HVAD) in preserving the multimeric structure of vWF. METHODS In total, 70 patients with implanted HM 3 (n = 35) or HVAD (n = 35) were retrospectively investigated. HMWMs, intermediate molecular weight multimers and low molecular weight multimers were quantified by using a densitometric methodology. vWF antigen, vWF activity and vWF collagen-binding activity, as well as demographic and clinical data, were analysed. RESULTS AvWS, which is characterized by a decrease in vWF HMWMs, was found in 97.1% of patients in the HM 3 group and 100% of patients in the HVAD group. Compared to normal pooled plasma, HM 3 induced a reduction in HMWMs (40.7 ± 8.2% vs 26.7 ± 7.5%, P < 0.01) and an increase in low molecular weight multimers (31.3 ± 11.8% vs 42.7 ± 9.8%, P < 0.01), whereas HVAD patients exhibited an increase in the percentage of intermediate molecular weight multimers (28.0 ± 5.0% vs 38.4 ± 7.7%, P < 0.01) in addition to a decrease in the percentage of HMWM (23.0 ± 11.0%, P < 0.01). A comparison of both left ventricular assist device types showed a difference in vWF multimeric structure (HMWMs: P < 0.01, intermediate molecular weight multimer: P = 0.05, low molecular weight multimer: P = 0.03). Furthermore, vWF activity was elevated in patients with an implanted HM 3 device (153.7 ± 54.4%) compared to those with an HVAD device (126.3 ± 39.7%, P = 0.02). CONCLUSIONS Patients with an implanted HM 3 had more intact HMWMs and a higher vWF activity during device support. This may reduce the manifestation of AvWS in HM 3 patients and could thus lead to a lower bleeding complication rate.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3