Longitudinal morphological changes of the aorta and the endograft position before and after distal stent graft-induced new entry in aortic dissections

Author:

Andic Mateja1,Mustafi Migdat1,Bonorden Constantin1,Grözinger Gerd2ORCID,Artzner Christoph2,Schlensak Christian1ORCID,Lescan Mario1

Affiliation:

1. Department of Thoracic and Cardiovascular Surgery, University Medical Center Tübingen , Tübingen, Germany

2. Department of Radiology, University Medical Center Tübingen , Tübingen, Germany

Abstract

Abstract OBJECTIVES The aim of this study was to assess the endograft position and aortic geometry changes after thoracic endovascular aortic repair (TEVAR) and frozen elephant trunk (FET) in distal stent-induced new entry (dSINE) patients. METHODS In this retrospective cohort study, the baseline demographic and the follow-up data were extracted from the hospital records, and computed tomography scans of dSINE patients after TEVAR or FET between 2011 and 2021 were analysed regarding endograft oversizing, length and migration, taper ratio, aortic diameter at the endograft end, aortic elongation (thoracic inner and outer curvature), wedge apposition angle and tortuosity angle in the distal landing zone. RESULTS dSINE was found in 22/213 (10%) of TEVAR and 10/31 (32%) of FET patients. The total follow-up time was 45 (27; 59) months. TEVAR was mainly performed with Relay NBS endograft (77%) and FET with Evita open prosthesis (80%). Paraplegia and stroke rates were 3%. dSINE occurred 17 (7; 35) months post-TEVAR and was instantly treated in 18 patients (56%) or followed up for 21 (11; 34) months (n = 14). Migration [+5 mm (1; 11; P < 0.001)], birdbeak angle [+9° (0; 27; P = 0.039)] and aortic diameter +5 mm (1; 11; P < 0.001) increased after dSINE, whereas aortic elongation increased already before [+12 mm (0; 27; P = 0.015)] and peaked after dSINE [+30 mm (9; 38; P < 0.001)]. The aortic elongation was more pronounced in the outer aortic curvature before and after dSINE (before: P = 0.039, after: P = 0.024). Postoperative wedge apposition [17° (12; 20)] increased before dSINE [21° (16; 35; P < 0.001)] and peaked thereafter [31° (21; 40; P < 0.001)]. CONCLUSIONS Aortic elongation may influence the endograft position and provoke TEVAR failure in the distal and proximal landing zones.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3