Are 18F-fluorodeoxyglucose positron emission tomography results reliable in patients with ascending aortic grafts? A prospective study in non-infected patients

Author:

Martínez-López Daniel1ORCID,Rodríguez Alfonso Begoña2,Ramos Martínez Antonio3,Martín López Carlos Esteban1,de Villarreal Soto Juan Esteban1,Ríos Rosado Elsa Carolina1,Villar García Susana1ORCID,Ospina Mosquera Víctor Manuel1,Serrano Fiz Santiago1,Burgos Lázaro Raúl1,García-Pavía Pablo1,Mitjavila Casanovas Mercedes2,Forteza Gil Alberto1ORCID

Affiliation:

1. Cardiac Surgery Department, Hospital Universitario Puerta de Hierro, Majadahonda, Madrid, Spain

2. Nuclear Medicine Department, Hospital Universitario Puerta de Hierro, Majadahonda, Madrid, Spain

3. Infectious Diseases Department, Hospital Universitario Puerta de Hierro, Majadahonda, Madrid, Spain

Abstract

Abstract OBJECTIVES Our goal was to define characteristic patterns of 18F-fluorodeoxyglucose in non-infected patients with ascending aortic prosthetic grafts during the first year after surgery. METHODS 18F-fluorodeoxyglucose positron emission tomography (PET)/computed tomography (CT) was performed at 3, 6 and 12 months postoperatively in 26 uninfected patients. Clinical, analytical and microbiological (blood culture) assessments were performed to confirm the absence of infection. FDG uptake intensity [measured through maximum standardized uptake values (SUVmax) and the target-to-background ratio] and distribution patterns were obtained. Models of generalized estimating equations were used to assess the evolution of the SUVmax over time. The results were compared to those in our endocarditis-over-ascending-aortic-graft series database. The receiver operating characteristic curves of the control group and the 12-month group were assessed. RESULTS All patients showed increased uptake in all areas. The uptake pattern was heterogeneous in 47.4%, 43.5% and 42.3% at 3, 6 and 12 months. The means and standard deviations of the SUVmax in the graft were 4.80 (±0.99), 4.28 (±0.88) and 4.14 (±0.87) at 3, 6 and 12 months after surgery. A comparison of all values obtained in the 6th and 12th months compared to those from the 3rd month revealed a slow decrease that may persist after the first year. The cut-off value of SUVmax of 4.24 had an overall sensitivity of 84.6% and specificity of 57.7% for patients seen at 12 months. CONCLUSIONS Non-infected ascending aortic grafts showed no predominant uptake pattern; they also showed increased 18F-fluorodeoxyglucose activity that could persist beyond the first year. Caution is therefore recommended when interpreting PET/CT images obtained during the first year after surgery.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3