The first report of transcatheter aortic valve-in-valve implantation within the expandable Inspiris Resilia® bioprosthetic valve

Author:

Mehdiani Arash1ORCID,Chekhoeva Agunda1ORCID,Klein Kathrin2,Lichtenberg Artur1ORCID

Affiliation:

1. Department of Cardiac Surgery, Heinrich Heine University Hospital , Düsseldorf, Germany

2. Department of Cardiology, Pneumology and Angiology, Heinrich Heine University Hospital , Düsseldorf, Germany

Abstract

Abstract A 61-year-old male who underwent aortic valve replacement with an Inspiris Resilia® aortic bioprosthetic through an upper partial sternotomy due to severe aortic valve stenosis was presented 1 year later to our hospital suffering from dyspnoea and chest pain. The transthoracic echocardiography demonstrated moderate haemodynamic structural valve deterioration with a mean gradient of 29 mmHg and a valve area of 0.9 cm2. Due to relatively high-risk of reoperation, valve-in-valve transcatheter aortic valve replacement with Sapien 3® 29 mm, followed by balloon valvuloplasty, was successfully performed. To the best of our knowledge, this is the first published case of valve-in-valve transcatheter aortic valve replacement into a degenerated Inspiris Resilia® aortic valve.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3