How to test adhesive strength: a biomechanical testing for aortic glue used in type a dissection repair

Author:

Zientara Alicja1ORCID,Tseng Yuan-Tsan23,Salmasi Yousuf Mohammad4,Quarto Cesare1,Stock Ulrich24

Affiliation:

1. Department of Cardiac Surgery, Royal Brompton Hospital, Part of Guy’s and St. Thomas’ NHS Foundation Trust , London, UK

2. Magdi Yacoub Institute , Harefield, UK

3. National Heart and Lung Institute, Imperial College London , London, UK

4. Department of Cardiac Surgery, Harefield Hospital, Part of Guy’s and St. Thomas’ NHS Foundation Trust , London, UK

Abstract

Abstract OBJECTIVES The aim of this study was to develop a method to quantify the peel force in an in vitro model simulating repair of ascending aortic dissections with tissue glue (Bioglue). METHODS This study adapted an adhesive T-Peel test for the determination of the peel strength of adhesives by measuring the peeling force of a T-shaped bonded tissue. Measurements were performed on iatrogenic dissected ascending porcine aorta, which has been repaired with Bioglue using different pressure levels. Four conditions were tested: zero sample pressure according to the manufacturer’s recommendation (n = 10), low (504 Pa; n = 11), moderate pressure (1711 Pa; n = 24) and pressure applied by a round shaped vascular ‘Borst clamp’ (1764 Pa; n = 23). Non-parametric one-way analysis of variance was applied for statistical significance. RESULTS The median peel force (lower quartile, upper quartile) of aortic samples increased depending on the applied pressure: [no pressure 0.030 N/mm (0.016, 0.057), low pressure 0.040 N/mm (0.032, 0.070) and moderate pressure 0.214 N/mm (0.050, 0.304)]. Samples pressurized with the Borst clamp reached 0.078 N/mm (0.046, 0.152), which was comparable to the peel force of the unpeeled controls [0.107 N/mm (0.087, 0.124)]. Compared to samples without pressure, Bioglue with the application of the Borst clamp (P = 0.021) and with moderate pressure (P = 0.0007) performed significantly better. CONCLUSIONS The novel T-Peel test offers an attractive method to test tissue glues in defined in vitro environments. Bioglue peel force increased with pressure on the aortic sample in contrast to low or no pressure as per the manufacturer’s recommendation. Modifying current recommended use may aid in increasing effectiveness of this approach.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Instructions for use: when and how to glue the dissected aorta;European Journal of Cardio-Thoracic Surgery;2023-09-29

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3