The arch remodelling stent for DeBakey I acute aortic dissection: experience with 100 implantations

Author:

Montagner Matteo1ORCID,Kofler Markus1ORCID,Seeber Fabian1ORCID,Pitts Leonard1,Starck Christoph12ORCID,Sündermann Simon H123ORCID,Kurz Stephan3ORCID,Grubitzsch Herko3ORCID,Falk Volkmar1234ORCID,Kempfert Jörg12

Affiliation:

1. Department of Cardiothoracic and Vascular Surgery, German Heart Center , Berlin, Germany

2. DZHK (German Centre for Cardiovascular Research), Partner Site Berlin , Berlin, Germany

3. Department of Cardiovascular Surgery, Charité—Universitaetsmedizin Berlin , Berlin, Germany

4. Department of Health Sciences and Technology, Translational Cardiovascular Technologies, Institute of Translational Medicine, Swiss Federal Institute of Technology (ETH) Zurich , Zurich, Switzerland

Abstract

Abstract OBJECTIVES A novel hybrid non-covered stent was developed to treat malperfusion and prevent aneurysm formation following hemiarch procedure for DeBakey I acute aortic dissection (AAD). The present analysis investigates the performance of the device in 100 consecutive implantations. METHODS Between 2018 and 2021, 100 patients underwent surgical repair of DeBakey I AAD with implantation of a non-covered stent in the arch and descending aorta. The primary entry tear was located in the root or the ascending aorta. Clinical and imaging data were collected and analysed retrospectively. The endpoints of the study were 30-day mortality, neurological outcome and need of additional procedures due to postoperative malperfusion. Technical success was assessed in the first postoperative computed tomography in regard to the induction of false lumen thrombosis in the descending aorta. RESULTS The median age was 61 (54–73) years. Preoperative malperfusion was present in 46 (46%) patients. The primary arterial cannulation strategy was the right axillary artery and an open distal anastomosis was performed in a median caudal circulatory arrest of 40 (34–52) min. In 48% of cases, a 55–40 tapered stent was implanted. The 30-day mortality was 18%, and the operation-related new postoperative neurological deficit was present in 8%. Technical success was achieved in 76% of patients. CONCLUSIONS The novel non-covered stent can be safely applied to complement aortic repair with the hemiarch procedure for DeBakey I AAD. The expansion of the true lumen through the device may prevent postoperative malperfusion and induces positive vascular remodelling with the thrombosis of the false lumen.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献