Capillary Blood Levels of Hydroxychloroquine and Methotrexate Are Stable for up to 5 Years When Collected on Volumetric Absorptive Microsamplers

Author:

Brady Kelley1,Alexander Roberta Vezza1,Stimson Deborah1,Rudolph Mark1,Kammesheidt Anja1

Affiliation:

1. Research and Development, Exagen Inc, 1261 Liberty Way, Suite C, Vista CA 92081

Abstract

Abstract Background Hydroxychloroquine (HCQ) and methotrexate (MTX) are common antirheumatic drugs used chronically by patients with systemic lupus erythematosus (SLE) and rheumatoid arthritis (RA) (1, 2). Therapeutic drug monitoring (TDM) of HCQ and MTX provides critical compliance information, but typically requires venipuncture and shipment of refrigerated blood samples to the clinical laboratory. Capillary blood collection by finger prick offers a convenient alternative to venipuncture. The long-term stability of capillary blood HCQ and MTX collected using volumetric absorptive microsamplers (VAMS) has not previously been evaluated. In this study, we evaluated the stability of capillary MTX and HCQ levels when stored on VAMS for up to 5 years. Methods Samples of patients with RA and SLE were collected for HCQ or MTX monitoring as part of 2 clinical studies in 2015 (HCQ: n = 24 | MTX: n = 61) and 2017 (HCQ: n = 126). Venous and capillary blood samples were shipped to Exagen Inc.’s clinical laboratory. HCQ and MTXPG3 were measured using separate LC-MS/MS methodologies. Baseline venous blood levels of HCQ and MTXPG3 were determined within 1 week of draw and compared to capillary blood levels determined following 3 or 5 years of storage. Results Venous blood HCQ and capillary blood MTXPG3 determinations made at baseline were significantly different from capillary blood determinations performed following 5 years of storage at −80 °C. However, these differences were within the specified limits of agreement [HCQ: Avg % change after storage (CI 95%) = −7.1% (−12.6, −1.6%), pt-test = 0.0205, interclass correlation coefficient (ICC) = 0.96 | MTXPG3: Avg % change after storage (CI 95%) = 13.3% (7.1, 19.4%), pt-test = 0.0001, ICC = 0.90]. Conclusion Dried capillary blood HCQ and MTXPG3 levels collected on VAMS are stable for up to 5 years.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3