Evaluation of Busulfan as a Third-Party Immunoassay on a Clinical Chemistry Analyzer

Author:

Zhou Janet R1,To Andrea2,Fritz James3,Jung Benjamin14,Yazdanpanah Mehrdad4,Kulasingam Vathany12

Affiliation:

1. Department of Laboratory Medicine and Pathobiology, University of Toronto , Toronto, ON , Canada

2. Division of Clinical Biochemistry, University Health Network , Toronto, ON , Canada

3. Saladax Biomedical, Inc. , Bethlehem, PA , United States

4. Division of Clinical Biochemistry, Department of Paediatric Laboratory Medicine, Hospital for Sick Children , Toronto, ON , Canada

Abstract

Abstract Background Busulfan is widely used in conditioning regimens to prepare patients for hematopoietic stem cell transplantation. Therapeutic drug monitoring (TDM) is critical due to large inter- and intra-individual variability in busulfan pharmacokinetics, and the risk of adverse consequences of toxicity including hepatic veno-occlusive disease. Busulfan is most commonly measured by liquid chromatography–mass spectrometry (LC-MS/MS), which is not as widely available in clinical laboratories as automated routine clinical chemistry analyzers. The objective was to perform analytical verification of a busulfan immunoassay on the Abbott Alinity c platform. Methods The MyCare Oncology busulfan immunoassay was configured as a third-party reagent on the Abbott Alinity c. Imprecision, linearity, sample carryover, and onboard stability of reagent studies were evaluated. The performance of the busulfan immunoassay using the Abbott Alinity c was compared to the Beckman Coulter AU480 using sodium heparinized plasma, as well as to LC-MS/MS using lithium heparinized plasma. Results The imprecision goal of 8% was met, and linearity within the analytical measurement range of 240 to 1700 ng/mL was verified. Sample carryover was negligible, and the reagents were stable onboard for at least 84 days. The busulfan immunoassay correlated well with LC-MS/MS (slope = 0.949, y-intercept = −7.8 ng/mL, r2 = 0.9935) and the Beckman Coulter AU480 (slope = 1.090, y-intercept = −34.5 ng/mL, r2 = 0.9988). Conclusions This study demonstrated successful analytical verification of a busulfan third-party immunoassay on the Abbott Alinity c platform. The ability to perform TDM of busulfan on a routine clinical chemistry analyzer will positively impact turnaround times to improve patient outcomes.

Funder

Busulfan MyCare Oncology

Publisher

Oxford University Press (OUP)