Improved Recognition of 25-Hydroxyvitamin D2 by 2 Automated Immunoassays

Author:

Geno K Aaron1,Tolan Nicole V2,Singh Ravinder J3,Nerenz Robert D1

Affiliation:

1. Department of Pathology and Laboratory Medicine, Dartmouth-Hitchcock Health System, Lebanon, NH; The Geisel School of Medicine at Dartmouth, Hanover, NH

2. Department of Pathology, Brigham and Women’s Hospital, Boston, MA; Harvard Medical School, Boston, MA

3. Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN

Abstract

Abstract Background Despite recommendations to limit vitamin D testing to specific clinical scenarios, test volume remains high in many clinical laboratories. Automated total vitamin D immunoassays frequently under- or over-recover 25-hydroxyvitamin D2 [25(OH)D2], making accurate assessment of vitamin D status difficult in patients taking high-dose 25(OH)D2 supplements. Mass spectrometry-based methods offer excellent recovery of 25(OH)D2 but are not practical for use in all laboratories. In this study, we evaluated 2 automated immunoassays against an LC–MS/MS method performed at a national reference laboratory. Methods A method comparison against LC–MS/MS was performed for the Roche Elecsys Vitamin D total II assay and the IDS-iSYS 25 VitDS immunoassays using 49 patient specimens submitted for clinical 25(OH)D measurement. Mean bias was calculated, and vitamin D status was determined for each specimen according to the 2011 Endocrine Society clinical practice guidelines. Results Theil–Sen regression lines relative to LC–MS/MS were y = 0.88x + 2.94 for Roche and y = 1.03x + 2.48 for IDS. Mean bias (±SD) in samples with 25(OH)D2 concentrations less than 5 ng/mL was −0.25 ng/mL (±6.30) for Roche and −1.45 ng/mL (±6.82) for the IDS. Mean bias (±SD) in samples with 25(OH)D2 concentrations greater than 5 ng/mL was −3.19 ng/mL (±6.61) for Roche and 5.52 ng/mL (±6.36) for IDS. Median percentage recovery of 25(OH)D2 was 87.1% (interquartile range 76.0–111.3) for Roche and 120.6% (interquartile range: 105.3–133.4) for IDS. Vitamin D status was misclassified in 7 samples by the Roche assay and 3 by the IDS assay. For all but one of the discordant pairs, the immunoassay result was within 1.7 ng/mL of the diagnostic cutoff. Conclusions The automated immunoassays evaluated here demonstrate improved recovery of 25(OH)D2 relative to previous generations. Both are acceptable for use in the determination of vitamin D status.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3