Chromogenic and Clot-Based Bivalirudin Assays for Monitoring Anticoagulation

Author:

Raghavendran Prashant1ORCID,Tillman Benjamin F2,Wheeler Allison P3,Gailani David3

Affiliation:

1. Division of Pediatric Hematology and Oncology, Department of Pediatrics, Vanderbilt University Medical Center , Nashville, TN , United States

2. Division of Hematology and Oncology, Department of Medicine, Vanderbilt University Medical Center , Nashville, TN , United States

3. Department of Pathology, Microbiology and Immunology, Vanderbilt University , Nashville, TN , United States

Abstract

Abstract Background Direct thrombin inhibitors (DTIs) are usually monitored with the activated partial thromboplastin time (aPTT) or activated clotting time (ACT). Both are complex assays with multiple enzymatic steps, and performance may be influenced by physiologic and pathologic factors unrelated to the DTI. Simpler systems, such as clot-based dilute thrombin time (dTT) and chromogenic anti-factor IIa assays, have been developed for monitoring DTIs, but there is limited data on their performance in clinical settings. Methods Medical records of patients who received bivalirudin between March 2020 and April 2022 at a single institution were reviewed for demographic data and adverse outcomes. Plasma samples drawn for aPTT testing were analyzed with chromogenic anti-IIa and dTT bivalirudin assays. Results were compared to bivalirudin dosing. Results Results of aPTT assays from 32 patients were compared with the chromogenic (n = 136) and dTT (n = 120) bivalirudin assays. Correlations between the aPTT and the chromogenic and dTT assays were poor (Spearman coefficients 0.55 and 0.62, respectively). There was a stronger correlation when results of the chromogenic and dTT assays were compared to each other (Spearman coefficient 0.92). When assay results were compared to bivalirudin dose, there were stronger correlations with the chromogenic and dTT assays than with the aPTT (Spearman coefficients 0.51, 0.63 and 0.22, respectively). Conclusions There was considerable variation between results of specific bivalirudin assays and the aPTT. While bivalirudin assay results correlated better with administered drug dose, suggesting improving reliability, more studies are needed to determine if there is correlation between testing and clinical outcomes.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3