Abstract

Abstract Background Heart failure remains a major cause of morbidity and mortality despite improvements in treatment. This study aimed to evaluate the Alere N-terminal pro B-type natriuretic peptide (NT-proBNP) immunoassay on the Abbott Alinity i platform. Methods The analytical performance including precision, linearity, limit of quantitation (LOQ), carryover, dilution-recovery, and stability was evaluated. A method comparison between the Abbott Alere NT-proBNP assay and Roche Elecsys proBNP II assay was performed using 70 residual plasma samples. Results Total imprecision was 4.1%, 3.5%, and 2.3% for low (120.9 ng/L), medium (333.9 ng/L), and high (4767.4 ng/L) QC levels, respectively. The manufacturer’s claimed LOQ of 8.3 ng/L was verified. Method comparison between the Alere NT-proBNP assay and the Elecsys proBNP II assay showed good agreement between assays with an R value of 0.998, a slope of 1.05 (95% CI, 1.03–1.06), and an intercept of 45.81 (95% CI, −46.6.84 to 138.22). The Bland–Altman plot showed an absolute bias of 250 ng/L or 6.02%. Subrange analysis (NT-proBNP <2000 ng/L) showed good agreement with an R value of 0.998, a slope of 1.04 (95% CI, 1.02–1.06), and an intercept of −4.83 (95% CI, −26.95 to 17.28), with a mean bias of 26 ng/L or 3.2%. The stability of NT-proBNP was also verified in lithium heparin plasma samples stored at 4°C over a 7-day period. Hemolysis and lipemia interference thresholds were verified, but icterus impacted NT-proBNP recovery by >20% at low analyte concentrations. Conclusions The Alere NT-proBNP assay demonstrated acceptable analytical performance and very good clinical concordance with the Elecsys proBNP II assay.

Funder

Abbott

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3