Comparison of Hb A1c Quantification in the Presence of Hemoglobin Variants of an HPLC Assay with an Enzymatic Assay

Author:

Nichols James H1ORCID,Berman Marvin2,Carrillo Alex3,Manning Suzanne1

Affiliation:

1. Department of Pathology, Microbiology and Immunology, Vanderbilt University Medical Center , Nashville, TN , United States

2. Abbott Laboratories, Core Diagnostics , Abbott Park, IL , United States

3. Abbott Laboratories, Rapid Diagnostics , Abbott Park, IL , United States

Abstract

Abstract Background In this study, we evaluated the impact of hemoglobin (Hb) variants on the performance of the Abbott Alinity c and Bio-Rad Variant II Turbo 2.0 HPLC Hb A1c assays. Methods The analytical performance of the Abbott Alinity c Hb A1c (enzymatic) assay was compared to the Bio-Rad Variant II Turbo 2.0 HPLC method using leftover whole blood EDTA samples with and without the presence of a hemoglobin variant. Assay precision was determined from an analysis of controls. Bias was estimated from analysis of a set of 40 samples analyzed by a Tosoh G8 HPLC instrument at the University of Missouri Diabetes Diagnostic Laboratory, an NGSP Secondary Reference Laboratory. Results Between-day precision was excellent for both methods (<3%). Bias met NGSP criteria of ±5% to target value. Correlation between the Alinity and Bio-Rad methods was good for patient samples without a hemoglobinopathy (y = 1.028x – 0.38, standard error of the estimate (SEE) = 0.16, n = 36, mean bias = −0.22). A total of 700 hemoglobin variant samples were evaluated on the 2 methods. Of the hemoglobin variants, 640/700 gave results on both methods: hemoglobin (Hb) S trait (n = 452), C trait (n = 131), D trait (n = 23), E trait (n = 26), and a mixture of other hemoglobinopathies (n = 8) including beta thalassemia, high hemoglobin F, transfused Hb SC, transfused Hb SD, and transfused Hb SS, or unknown variant. There was good agreement for the 640 Hb variants between the methods with a range of mean differences of −0.10 to +0.06 depending on the variant, but more variability (SEE 0.25 to 0.39). Sixty samples did not have paired results. Conclusions To our knowledge, this study was the largest investigation of the effect of hemoglobinopathies on the Abbott Alinity c Hb A1c assay. Analytical performance varied depending on the specific hemoglobin variant trait when compared to the Bio-Rad Variant II Turbo 2.0 HPLC method.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3