Establishing the Reportable Interval for Routine Clinical Laboratory Tests: A Data-Driven Strategy Leveraging Retrospective Electronic Medical Record Data

Author:

Zayed Ahmed M12ORCID,Saegeman Veroniek3,Delvaux Nicolas1

Affiliation:

1. Department of Public Health and Primary Care, KU Leuven , Leuven , Belgium

2. Laboratory Medicine Department, Menoufia University National Liver Institute , Shebin El-Kom , Egypt

3. Vitaz Sint-Niklaas Moerland, Clinical Laboratory , Sint-Niklaas, Oost-Vlaanderen , Belgium

Abstract

Abstract Background This paper presents a data-driven strategy for establishing the reportable interval in clinical laboratory testing. The reportable interval defines the range of laboratory result values beyond which reporting should be withheld. The lack of clear guidelines and methodology for determining the reportable interval has led to potential errors in reporting and patient risk. Methods To address this gap, the study developed an integrated strategy that combines statistical analysis, expert review, and hypothetical outlier calculations. A large data set from an accredited clinical laboratory was utilized, analyzing over 124 million laboratory test records from 916 distinct tests. The Dixon test was applied to identify outliers and establish the highest and lowest non-outlier result values for each test, which were validated by clinical pathology experts. The methodology also included matching the reportable intervals with relevant Logical Observation Identifiers Names and Codes (LOINC) and Unified Code for Units of Measure (UCUM)-valid units for broader applicability. Results Upon establishing the reportable interval for 135 routine laboratory tests (493 LOINC codes), we applied these to a primary care laboratory data set of 23 million records, demonstrating their efficacy with over 1% of result records identified as implausible. Conclusions We developed and tested a data-driven strategy for establishing reportable intervals utilizing large electronic medical record (EMR) data sets. Implementing the established interval in clinical laboratory settings can improve autoverification systems, enhance data reliability, and reduce errors in patient care. Ongoing refinement and reporting of cases exceeding the reportable limits will contribute to continuous improvement in laboratory result management and patient safety.

Publisher

Oxford University Press (OUP)

Reference22 articles.

1. Reportable interval of patient examination results and ISO 15189;Suárez-Vega;Clin Chem Lab Med,2005

2. Letter to the editor: unlikeliness limits estimation;Solé-Enrech;EJIFCC,2010

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3