Analytical Performance Evaluation of a New Calcitonin Assay

Author:

Moretti Giacomo1ORCID,Troiani Eliana1,Sarlo Francesca2,Baroni Silvia12,Urbani Andrea12

Affiliation:

1. Dipartimento di Chimica Biochimica e Biologia Molecolare Clinica, Fondazione Policlinico Universitario A. Gemelli I.R.C.C.S., Rome, Italy

2. Faculty of Medicine and Surgery, Università Cattolica del Sacro Cuore, Rome, Italy

Abstract

Abstract Background The use of efficient laboratory calcitonin (CT) testing is required for optimal management of medullary thyroid carcinoma. Several pitfalls are related to the calcitonin laboratory assays and a careful evaluation is needed. We report the analytical performances of the new Siemens ADVIA-Centaur-CALCT (CT-XPT) assay and its comparison with our standard method DiaSorin-Calcitonin-II-Gen (CT-LIA) assay. Methods Analytical performance of the CT-XPT-assay, limit of blank (LOB), limit of detection (LOD), and limit of quantification (LOQ), were determined. We also evaluated the in vitro stability of the sample, together with the linearity and percentage recovery. Results The CT-XPT-assay showed a better detection limit than the CT-LIA assay, with lower values of LOB (0.86 pg/mL vs 1.00 pg/mL) and LOQ (1.65 pg/mL vs 3.00 pg/mL). Both values were in agreement with those reported by the manufacturer. Within- and between-run precision demonstrated a good concordance of results. Regarding the in vitro stability of CT, the low CT concentration sera showed a much greater decrease in CT levels compared to the high concentration sera. Correlation studies showed a good correlation between the two methods (Kappa Cohen coefficent, KC: 0.68, agreement % for male: 89.58%; KC: 0.63; agreement % for female: 88.33%). Conclusions Our findings showed a good correlation between the CT-LIA and CT-XPT methods. Moreover, we demonstrated that the analytical performance of the CT-XPT assay, together with its technical specifications, could represent major features of the CT-XPT method. Collectively, the technical evaluation and the analytical results described in the presented paper highlight that the novel CT-XPT is a valid method for CT testing in a clinical diagnostic setting.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3