Evaluation of an Electrochemiluminescent SARS-CoV-2 Antibody Assay

Author:

Lau C S1,Hoo S P1,Yew S F1,Ong S K2,Lum L T2,Heng P Y3,Tan J G3,Wong M S3,Aw T C1245

Affiliation:

1. Department of Laboratory Medicine, Changi General Hospital, Singapore

2. Department of Pathology, Sengkang General Hospital, Singapore

3. Department of Laboratory Medicine, Khoo Teck Puat Hospital, Singapore

4. Department of Medicine, National University of Singapore, Singapore

5. Academic Pathology Program, Duke-NUS Medical School, Singapore

Abstract

Abstract Background Little is known about the performance of the Roche novel severe acute respiratory syndrome coronavirus 2 antibody (anti-SARS-CoV-2) assay. We provide an extensive evaluation of this fully automated assay on Cobas e801/e602 immunoassay analyzers. Methods We assessed the linearity, precision, and throughput of the Roche anti-SARS-CoV-2 assay. Sensitivity was calculated from 349 SARS-CoV-2 polymerase chain reaction (PCR) positive samples; specificity was determined from 715 coronavirus disease 2019 (COVID-19)-naive samples. We examined cross-reactivity against other antibody positive samples [syphilis, rheumatoid factor (RF), antinuclear antibody (ANA), double-stranded DNA (ds-DNA), influenza, dengue, hepatitis B (HBV), hepatitis C (HCV)] and the anti-SARS-CoV-2 kinetics. Results The assay cut-off index (COI) was linear up to 90.8. The interassay precision was 2.9% for a negative control (COI = 0.1) and 5.1% for a positive control (COI = 3.0). Assay time is 18 min and results are available 1 min later; throughput for 300 samples was 76 min. Only 1 case positive for HBsAg tested falsely positive; specificity was 99.9%. The assay has a sensitivity of 97.1% 14 days after PCR positivity (POS) and 100% at ≥21 days POS; 48.2% of cases had anti-SARS-CoV-2 within 6 days POS. In 11 patients in whom serum was available prior to a positive antibody signal (COI ≥1.0) the interval between the last negative and first positive COI (time to “seroconversion”) on average is 3 days (range 1–6 days) and 4 more days (range 1–7) for the anti-SARS-CoV-2 to plateau. Conclusion The Roche anti-SARS-CoV-2 assay shows excellent performance with minimal cross-reactivity from other viral and confounding antibodies. Antibody development and seroconversion appears quite early.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

Reference24 articles.

1. Mild or moderate Covid-19;Gandhi;N Engl J Med,2020

2. Severe Covid-19;Berlin;N Engl J Med,2020

3. Estimates of the severity of coronavirus disease 2019: a model-based analysis;Verity;Lancet,2020

Cited by 24 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献