Affiliation:
1. Lockheed Environmental Systems & Technologies Co., 980 Kelly Johnson Dr, Las Vegas, NV 89119
2. U.S. Environmental Protection Agency, National Exposure Research Laboratory, Characterization Research Division, PO Box 93478, Las Vegas, NV 89193-3478
Abstract
Abstract
A comprehensive screening and confirmatory method was developed for monitoring polychlorinated biphenyls (PCBs), both as Aroclors and as individual congeners. This approach incorporates extraction, extract cleanup, and analysis modules designed to match cost, time, and data quality requirements. Soxhlet, sonication, supercritical fluid, and accelerated solvent extractions were evaluated. Carbon chromatographic cleanup procedures were used for separation of congeners on the basis of ortho substitutions, which permitted calculation of toxicity equivalents. Individual congener determinations, congener total histograms, and peak comparison techniques for Aroclor identification were elaborated by using high and low resolution mass spectrometricdata. A screening procedure based on immunoassay using the Ohmicron PCB RaPID AssayTM kit gave results comparable to those obtained by gas chromatography with electron capture detection in the range 0.40-230 ppm, when the appropriate Aroclor calibrator was used.
Publisher
Oxford University Press (OUP)
Subject
Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献