Prediction of proton beam range in phantom with metals based on monochromatic energy CT images

Author:

Meng Qianqian1,Li Jing1,Jiang Wei234,Hu Birong5,Xu Feng67,Shi Xiaomeng8,Zhong Renming9

Affiliation:

1. Radiophysical Technology Center , Cancer Center, West China Hospital, Sichuan University, Chengdu, 610041 , China

2. Department of Radiotherapy , Yantai Yuhuangding Hospital, Yantai, 264000 , China

3. Academy of Medical Engineering and Translational Medicine , Department of Biomedical Engineering, School of Precision Instrument and Opto-electronics Engineering, , Tianjin, 300072 , China

4. Tianjin University , Department of Biomedical Engineering, School of Precision Instrument and Opto-electronics Engineering, , Tianjin, 300072 , China

5. Department of Radiotherapy, Chengdu Second People’s Hospital , Chengdu, 610021 , China

6. Lung Cancer Center & Institute , West China Hospital, , Chengdu, 610041 , China

7. Sichuan University , West China Hospital, , Chengdu, 610041 , China

8. CT Imaging Research Center, GE Healthcare China , Shanghai, 201203 , China

9. Radiophysical Technology Center, Cancer Center, West China Hospital, Sichuan University , Chengdu, 610041 , China

Abstract

Abstract The purpose of the study was to evaluate the accuracy of monochromatic energy (MonoE) computed tomography (CT) images reconstructed by spectral CT in predicting the stopping power ratio $( SP{R}_w)$ of materials in the presence of metal. The CIRS062 phantom was scanned three times using spectral CT. In the first scan, a solid water insert was placed at the center of the phantom $(C{T}_{no\ metal})$. In the second scan, the solid water insert was replaced with a titanium alloy femoral head $(C{T}_{metal})$. The metal artifact reduction (MAR) algorithm was used in the last scan $(C{T}_{metal+ MAR})$. The MonoE-CT images of 40 keV and 80 keV were reconstructed. Finally, the single-energy CT method (SECT) and the dual-energy CT method (DECT) were used to calculate the $SP{R}_w$. The mean absolute error (MAE) of the $SP{R}_w$ of the inner layer inserts calculated by the SECT method were 3.19%, 13.88% and 2.71%, corresponding to $C{T}_{no\ metal}$, $C{T}_{metal}$ and $C{T}_{metal+ MAR}$, respectively. For the outer layer inserts, the MAE of $SP{R}_w$ were 3.43%, 5.42% and 2.99%, respectively. Using the DECT method, the MAE of the $SP{R}_w$ of the inner layer inserts was 1.30%, 3.69% and 1.46% and the MAE of the outer layer inserts– was 1.34%, 1.36% and 1.05%. The studies shows that, compared with the SECT method, the accuracy of the DECT method in predicting the $SP{R}_w$ of a material is more robust to the presence of metal. Using the MAR algorithm when performing CT scans can further improve the accuracy of predicting the SPR of materials in the presence of metal.

Funder

West China Hospital, Sichuan University

Science and Technology Support Program of Sichuan Province, China

Publisher

Oxford University Press (OUP)

Subject

Health, Toxicology and Mutagenesis,Radiology, Nuclear Medicine and imaging,Radiation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3