Dosimetric effect of set-up error in accelerator-based boron neutron capture therapy for head and neck cancer

Author:

Komori Shinya1,Hirose Katsumi23,Sato Mariko23,Takeuchi Akihiko1,Kato Ryohei1,Motoyanagi Tomoaki1,Harada Takaomi1,Yamazaki Yuhei1,Harada Mayumi2,Narita Yuki1,Kato Takahiro14,Takai Yoshihiro2

Affiliation:

1. Department of Radiation Physics and Technology, Southern Tohoku BNCT Research Center , 7-10 Yatsuyamada, Koriyama, Fukushima, 963-8052 , Japan

2. Department of Radiation Oncology, Southern Tohoku BNCT Research Center , 7-10 Yatsuyamada, Koriyama, Fukushima, 963-8052 , Japan

3. Department of Radiation Oncology, Hirosaki University Graduate School of Medicine , 5 Zaifu-cho, Hirosaki, Aomori, 036-8562 , Japan

4. School of Health Sciences, Fukushima Medical University , 10-6 Sakaemachi, Fukushima, Fukushima, 960-8516 , Japan

Abstract

Abstract The dosimetric effect of set-up error in boron neutron capture therapy (BNCT) for head and neck cancer remains unclear. In this study, we analyzed the tendency of dose error by treatment location when simulating the set-up error of patients. We also determined the tolerance level of the set-up error in BNCT for head and neck cancer. As a method, the distal direction was shifted with an interval of 2.5 mm, from 0.0 mm to +20.0 mm and compared with the dose at the reference position. Similarly, the horizontal direction and vertical direction were shifted, with an interval of 5.0 mm, from −20.0 mm to +20.0 mm. In addition, cases with 3.0 mm and 5.0 mm simultaneous shifts in all directions were analyzed as the worst-case scenario. The dose metrics of the minimum dose of the tumor and the maximum dose of the mucosa were evaluated. From unidirectional set-up error analysis, in most cases, the set-up errors with dose errors within ±5% were Δdistal < +2.5 mm, Δhorizontal < ±5.0 mm and Δvertical < ±5.0 mm. In the simulation of 3.0 mm shifts in all directions, the errors in the minimum tumor dose and maximum mucosal dose were −3.6% ±1.4% (range, −5.4% to −0.6%) and 2% ±1.4% (range, 0.4% to 4.5%), respectively. From these results, if the set-up error was within ±3.0 mm in each direction, the dose errors of the tumor and mucosa could be suppressed within approximately ±5%, which is suggested as a tolerance level.

Publisher

Oxford University Press (OUP)

Subject

Health, Toxicology and Mutagenesis,Radiology, Nuclear Medicine and imaging,Radiation