Abstract

Abstract Introduction In cases of a noninfected malfunctioning inflatable penile prosthesis (IPP) device, surgeons often opt to exchange all of the device rather than the defective component for fear of an increased infection rate and future mechanical dysfunction. Objectives To assess whether partial-component exchange of an IPP device has comparable outcomes to complete explant and replacement of an IPP device with or without a retained reservoir. Methods A systematic review was conducted following the PRISMA 2020 and AMSTAR guidelines. Searches were performed on MEDLINE (Ovid), PubMed, and the Cochrane Library from inception to June 2023, identifying studies reporting outcomes and complications of revision surgery for noninfected malfunctioning IPP devices. Three groups were compared: those undergoing single- or 2-component exchange, those with complete explantation and replacement, and those with replacement of all components while retaining the primary reservoir. Results Analysis included 11 articles comprising 12 202 patients with complete device replacement, 234 with partial device exchange, and 151 with retained reservoirs following revision. Mean ages ranged from 62 to 68 years, with median follow-up times between 3 and 84 months. Partial-component exchange showed a higher infection rate (6.3%) as compared with complete replacement (2.7%) and reservoir retention (3.9%). Similarly, partial exchange had a higher complication rate (23.9%) when compared with complete replacement (11.3%) and reservoir retention (19.6%). Mechanical failure rates for partial exchange were similar across the 3 groups (10%, 2.8%, and 5.8%, respectively). Conclusion Partial-component exchange during IPP revision is associated with higher infection and perioperative complication rates but comparable rates of mechanical failure as compared with complete-component replacement, with or without retaining the original reservoir.

Publisher

Oxford University Press (OUP)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3