Affiliation:
1. Occupational Lung Disease Unit, Birmingham Heartlands Hospital , Birmingham B9 5SS , UK
Abstract
Abstract
Background
Work-related asthma symptoms are common in teachers and teaching assistants, there are few studies evaluating their causes.
Aims
To identify causes of occupational asthma in teachers and teaching assistants referred to the Birmingham Occupational Lung Disease clinic 2000–20 using evaluation of serial Peak Expiratory Flow (PEF) records.
Methods
Teachers and teaching assistants with possible occupational asthma were asked to record PEF 2-hourly at home and work for 4 weeks. Their records were evaluated with the Oasys programme. Those with a positive score for any of the three scores (area between curves (ABC), timepoint and Oasys score from discriminant analysis) were included. Repeat records were made as indicated to help identify the cause and the effects of remedial actions.
Results
Thirty-eight teachers or teaching assistants met the inclusion criteria with all three Oasys scores positive in 24, 2/3 scores in nine and 1/3 in five. The building was the likely cause in 17 (in new builds particularly acrylates from carpet adhesives and in old buildings mould and construction dust), bystander exposure to agents in the schools in 12 (cleaning agents, acrylates from photocopiers and chloramines from indoor pools) and materials used in the classroom in 9 (most commonly MDF in design and technology classes). We illustrate how the PEF records helped identify the cause.
Conclusions
Oasys analysis of PEF records is a useful method of evaluating occupational asthma in teachers and identified difficult to confirm causes where successful remediation or redeployment was achieved.
Publisher
Oxford University Press (OUP)
Subject
Public Health, Environmental and Occupational Health
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献