An improved method for measuring catalase activity in biological samples

Author:

Hadwan Mahmoud Hussein1ORCID,Hussein Marwah Jaber1,Mohammed Rawa M2,Hadwan Asad M34,Saad Al-Kawaz Hawraa5,Al-Obaidy Saba S M1,Al Talebi Zainab Abbas1

Affiliation:

1. Department of Chemistry, College of Science, University of Babylon , Hilla 51002, Iraq

2. Department of Medical Physics, University of Al-Mustaqbal , Hilla 51001, Iraq

3. Faculty of Natural Sciences, University of Tabriz , Tabriz, po 5166616471, Iran

4. Al-Manara College for Medical Sciences , Al-Amarah 62001, Iraq

5. Department of Medical Laboratories Techniques, University of Al-Mustaqbal , Hilla 51001, Iraq

Abstract

Abstract Catalase (CAT) is an important enzyme that protects biomolecules against oxidative damage by breaking down hydrogen peroxide (H2O2) into water and oxygen. CAT is present in all aerobic microbes, animals, and plants. It is, however, absent from normal human urine but can be detected in pathological urine. CAT testing can thus help to detect such urine. This study presents a novel spectrophotometric method for determining CAT activity characterized by its simplicity, sensitivity, specificity, and rapidity. The method involves incubating enzyme-containing samples with a carefully chosen concentration of H2O2 for a specified incubation period. Subsequently, a solution containing ferrous ammonium sulfate (FAS) and sulfosalicylic acid (SSA) is added to terminate the enzyme activity. A distinctive maroon-colored ferrisulfosalicylate complex is formed. The formation of this complex is a direct result of the reaction between FAS and any residual peroxide present. This leads to the generation of ferric ions when coordinated with SSA. The complex has a maximum absorbance of 490 nm. This advanced method eliminates the need for concentrated acids to stop CAT activity, making it safer and easier to handle. A comparative analysis against the standard ferrithiocyanate method showed a correlation coefficient of 0.99, demonstrating the new method’s comparable effectiveness and reliability. In conclusion, a simple and reliable protocol for assessing CAT activity, which utilizes a cuvette or microplate, has been demonstrated in this study. This interference-free protocol can easily be used in research and clinical analysis with considerable accuracy and precision.

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3