Sensitivity and specificity of thromboelastography for hyperfibrinolysis: Comparison of TEG 5000 and TEG 6S CK LY30 systems

Author:

Fuja Christine1ORCID,Carll Timothy C1ORCID,Mikrut Krzysztof2,Wool Geoffrey D1

Affiliation:

1. Department of Pathology, University of Chicago , Chicago, IL , US

2. Clinical Laboratories, University of Chicago Medicine , Chicago, IL , US

Abstract

Abstract Objectives The sensitivity and specificity of clot lysis at 30 minutes after maximum clot strength (LY30), as measured by thromboelastography (TEG), for clinically significant hyperfibrinolysis have not been compared across the 2 US Food and Drug Administration–approved instruments (the TEG 5000 and TEG 6s [Haemonetics]). Methods We performed a retrospective, single-center analysis of these 2 instruments using the kaolin (CK) reagent. Results Local verification studies showed that the TEG 5000 and TEG 6s CK LY30 upper limits of normal (ULNs) were distinct (5.0% and 3.2%, respectively). Retrospective analysis of patient data showed that abnormal LY30 was 6 times more prevalent with the TEG 6s than with the TEG 5000 instrument. LY30 was a significant predictor of mortality with both instruments (TEG 6s: receiver operating characteristic [ROC] area under the curve [AUC] = 0.836, P ≤ .0001; TEG 5000: ROC AUC = 0.779, P = .028). The optimal LY30 cut point was determined based on these mortality data for each instrument. The TEG 6s showed superior mortality prediction than the TEG 5000 at lower LY30 levels (≥10%), with likelihood ratios of 8.22 and 2.62 for the TEG 6s and TEG 5000, respectively. Patients with a TEG 6s CK LY30 of 10% or higher were significantly more likely to die, receive cryoprecipitate, receive transfusions, or receive massive transfusion than patients with a TEG 6s LY30 of 3.3% to 9.9% (all P < .01). Patients with a TEG 5000 LY30 of 17.1% or higher were significantly more likely to die or use cryoprecipitate (P < .05); transfusion and massive transfusion protocol were not significantly different. Whole blood spiking studies showed that 70 ng/mL tissue plasminogen activator (tPA) achieved an average LY30 of approximately 10% for both instruments. Conclusions CK LY30 above the ULN is a sensitive but not specific cutoff for hyperfibrinolysis. At least moderately elevated CK LY30 carries more clinical portent on the TEG 6s instrument than on the TEG 5000. These TEG instruments are not sensitive to low concentrations of tPA.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3