Affiliation:
1. Vanderbilt University School of Medicine, Nashville, TN, USA
2. Department of Pathology, Microbiology and Immunology, Vanderbilt University School of Medicine, Nashville, TN, USA
Abstract
Abstract
Objectives
To determine optimal temperature profiles for 2 uniquely designed courier lockboxes (steel vs polymer) by standardizing daily ice (–20ºC) and cold (4-8ºC) pack placement.
Methods
Paired courier lockboxes were placed outside in direct sunlight. Ambient outdoor and lockbox temperatures were monitored during 2 4-day cycles, and temperature mean and range were determined daily (time frame, 4:00-10:00 pm). Control lockboxes without packs were compared with experimental paired lockboxes with either 2 cold packs placed at 4:00 pm or 4 ice packs placed at 8:00 am and replaced with 4 cold packs at 4:00 pm daily.
Results
Cycle 1 mean temperatures within control steel and polymer lockboxes were 31.8ºC (range, 18.4-44.1ºC) and 37.2ºC (range, 27.1-46.7ºC), respectively. The addition of 2 cold packs at 4:00 pm reduced mean temperatures to 29.1ºC (range, 19.1-37.2ºC) and 25.3ºC (range, 20.0-31.6ºC) in steel and polymer boxes, respectively. Cycle 2 mean temperatures within control steel and polymer lockboxes were 28.3ºC (range, 22.4-40.8ºC) and 31.6ºC (range, 23.8-41.0ºC), respectively. The addition of 4 ice packs at 8:00 am and replacement with 4 cold packs at 4:00 pm reduced mean temperatures to 24.3ºC (range, 17.4-27.9ºC) and 13.4ºC (range, 6.6-18.1ºC) in steel and polymer boxes, respectively.
Conclusions
Standardizing instructions for ice and cold packs can decrease internal courier lockbox temperatures.