Permanent pacemaker implantation following transcatheter aortic valve implantation using self-expandable, balloon-expandable, or mechanically expandable devices: a network meta-analysis

Author:

Ravaux Justine M1ORCID,Di Mauro Michele1ORCID,Vernooy Kevin234ORCID,Kats Suzanne1,Mariani Silvia1ORCID,Ronco Daniele15,Actis Dato Giulia1,Simons Jorik1,Hof Arnoud W. Van’t23,Maessen Jos G13,Lorusso Roberto13ORCID

Affiliation:

1. Departement of Cardio-Thoracic Surgery, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan, 25, 6202 AZ Maastricht, The Netherlands

2. Department of Cardiology, Maastricht University Medical Centre (MUMC), Maastricht, The Netherlands

3. Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands

4. Department of Cardiology, Radboud University Medical Center (Radboudumc), Nijmegen, The Netherlands

5. Department of Medicine and Surgery, Circolo Hospital, University of Insubria, Varese, Italy

Abstract

Abstract Aims Permanent pacemaker implantation (PPI) still limits the expansion of indications for transcatheter aortic valve implantation (TAVI). Comparison between different systems remains scarce. We aimed to determine the impact of the device type used on post-TAVI PPI. Methods and results A systematic literature review was performed to identify studies reporting the use of balloon-expandable valve (BEV), self-expandable valve (SEV), and mechanically expandable valve (MEV) and post-TAVI PPI. A network meta-analysis was used to compare TAVI mechanisms (Analysis A) and transcatheter heart valves (Analysis B) with respect to post-TAVI PPI. Analysis A included 40 181 patients with a pooled PPI rate of 19.2% in BEV, 24.7% in SEV, and 34.8% in MEV. Balloon-expandable valve showed lower risk compared to either SEV or MEV and SEV demonstrated lower risk for PPI than MEV. Implantation of BEV was associated with 39% and 62% lower PPI rate with respect to SEV and MEV. Implantation of SEV was associated with 38% lower PPI rate with respect to MEV. Analysis B included 36.143 patients with the lowest pooled PPI rate of 9.6% for Acurate Neo or others, and the highest pooled PPI rate of 34.3% for Lotus. CoreValve, Evolut Portico, and Lotus influenced significantly PPI rate, while Sapien group did not. Conclusion Implantation of BEV and also SEV were associated with lower post-TAVI PPI rate, while MEV were associated with higher post-TAVI PPI. Patient tailored-approach including devices characteristics may help to reduce post-TAVI PPI and to allow TAVI to take the leap towards extension of use in younger patients. Prospero number CRD42021238671.

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3