Non-invasive detection of slow conduction with cardiac magnetic resonance imaging for ventricular tachycardia ablation

Author:

Vázquez-Calvo Sara12ORCID,Mas Casanovas Judit1ORCID,Garre Paz12ORCID,Sánchez-Somonte Paula12ORCID,Falzone Pasquale Valerio12ORCID,Uribe Laura12ORCID,Guasch Eduard123ORCID,Tolosana José Maria123ORCID,Borras Roger124ORCID,Figueras i Ventura Rosa M5ORCID,Arbelo Elena123ORCID,Ortiz-Pérez José T123ORCID,Prats Susana12,Perea Rosario J12ORCID,Brugada Josep123ORCID,Mont Lluís123ORCID,Porta-Sanchez Andreu12ORCID,Roca-Luque Ivo123ORCID

Affiliation:

1. Institut Clinic Cardiovascular, Hospital Clínic, Universitat de Barcelona , Villarroel, 170 , 08036 Barcelona, Spain

2. Institut d’Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS) , Barcelona , Spain

3. Centro de Investigación Biomédica en Red, Enfermedades Cardiovasculares (CIBERCV) , Madrid , Spain

4. Centro de Investigación Biomédica en Red e Salud Mental, CIBERSAM, Instituto de Salud Carlos III, Madrid, Spain

5. ADAS 3D Medical S.L., Barcelona, Spain

Abstract

Abstract Aims Non-invasive myocardial scar characterization with cardiac magnetic resonance (CMR) has been shown to accurately identify conduction channels and can be an important aid for ventricular tachycardia (VT) ablation. A new mapping method based on targeting deceleration zones (DZs) has become one of the most commonly used strategies for VT ablation procedures. The aim of the study was to analyse the capability of CMR to identify DZs and to find predictors of arrhythmogenicity in CMR channels. Methods and results Forty-four consecutive patients with structural heart disease and VT undergoing ablation after CMR at a single centre (October 2018 to July 2021) were included (mean age, 64.8 ± 11.6 years; 95.5% male; 70.5% with ischaemic heart disease; a mean ejection fraction of 32.3 ± 7.8%). The characteristics of CMR channels were analysed, and correlations with DZs detected during isochronal late activation mapping in both baseline maps and remaps were determined. Overall, 109 automatically detected CMR channels were analysed (2.48 ± 1.15 per patient; length, 57.91 ± 63.07 mm; conducting channel mass, 2.06 ± 2.67 g; protectedness, 21.44 ± 25.39 mm). Overall, 76.1% of CMR channels were associated with a DZ. A univariate analysis showed that channels associated with DZs were longer [67.81 ± 68.45 vs. 26.31 ± 21.25 mm, odds ratio (OR) 1.03, P = 0.010], with a higher border zone (BZ) mass (2.41 ± 2.91 vs. 0.87 ± 0.86 g, OR 2.46, P = 0.011) and greater protectedness (24.97 ± 27.72 vs. 10.19 ± 9.52 mm, OR 1.08, P = 0.021). Conclusion Non-invasive detection of targets for VT ablation is possible with CMR. Deceleration zones found during electroanatomical mapping accurately correlate with CMR channels, especially those with increased length, BZ mass, and protectedness.

Funder

Instituto de Salud Carlos III

European Union

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3