Non-traditional implantable cardioverter-defibrillator configurations and insertion techniques: a review of contemporary options

Author:

Tonko Johanna B12ORCID,Rinaldi Christopher A12

Affiliation:

1. Department of Cardiology, St. Thomas’ Hospital, Westminster Bridge Rd, London SE1 7EH, UK

2. Department of Cardiovascular Imaging, Arrhythmia Research Group, King’s College London, School of Biomedical Engineering & Imaging Sciences, London, UK

Abstract

Abstract Implantable cardioverter-defibrillators (ICDs) have revolutionized the treatment of acquired or inherited cardiac diseases associated with a high risk of sudden cardiac death due to ventricular tachyarrhythmias. Contemporary ICD devices offer reliable arrhythmia detection and discrimination algorithms and deliver highly efficient tachytherapies. Percutaneously inserted transvenous defibrillator coils with pectoral generator placement are the first-line approach in the majority of adults due to their extensively documented clinical benefit and efficiency with comparably low periprocedural implantation risks as well as the option of providing pain-free tachycardia treatment via anti-tachycardia pacing (ATP), concomitant bradycardiaprotection, and incorporation in a cardiac resynchronization therapy if indicated. Yet, expanding ICD indications particularly among younger and more complex patient groups as well as the increasingly evident long-term consequences and complications associated with intravascular lead placements promoted the development of alternative ICD configurations. Most established in daily clinical practice is the subcutaneous ICD but other innovative extravascular approaches like epicardial, pericardial, extra-pleural, and most recently substernal defibrillator coil placements have been introduced as well to overcome shortcomings associated with traditional devices and allow for individualized treatment strategies tailored to the patients characteristics and needs. The review aims to provide practical solutions for common complications encountered with transvenous ICD systems including restricted venous access, high defibrillation/fibrillation thresholds (DFTs), and recurrent device infections. We summarize the contemporary options for non-traditional extravascular ICD configurations outlining indications, advantages, and disadvantages.

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference76 articles.

1. EHRA International consensus document on how to prevent, diagnose and treat cardiac implantable electronic device infections;Lundqvist;Europace,2020

2. Venous stenosis and occlusion in the presence of endocardial leads;Boczar;Adv Clin Exp Med,2016

3. Increasing hazard of Sprint Fidelis implantable cardioverter-defibrillator lead failure;Hauser;Heart Rhythm,2009

4. A systematic review of ICD complications in randomised controlled trials versus registries: is our ‘real-world’ data an underestimation?;Ezzat;Open Heart,2015

5. Cardiac perforation from implantable cardioverter defibrillator lead placement. Insights from the National;Hsu;Circ Cardiovasc Qual Outcomes,2013

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献