Affiliation:
1. Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, DK-8200 Aarhus N, Denmark
Abstract
Abstract
Aims
Contact force (CF) sensing has emerged as a tool to guide and improve outcomes for catheter ablation (CA) for cardiac arrhythmias. The clinical benefit on patient outcomes remains unknown. To study whether CF-guided CA for typical atrial flutter (AFL) is superior to CA not guided by CF.
Methods and results
In a double-blinded controlled superiority trial, we randomized patients 1:1 to receive CA for typical AFL guided by CF (intervention group) or blinded to CF (control group). In the intervention group, a specific value of the lesion size index (LSI), estimating ablation lesions size was targeted for each ablation lesion. Patients underwent electrophysiological study (EPS) after 3 months to assess occurrence of the primary endpoint of re-conduction across the cavo-tricuspid isthmus (CTI). We included 156 patients with typical AFL, median age was 68 [interquartile range (IQR) 61–74] years and 120 (77%) patients were male. At index procedure median LSI was higher in the intervention group [6.4 (IQR 5.1–7) vs. 5.6 (IQR 4.5–6.9), P < 0.0001]. After 3 months, 126 patients (58 in intervention group) underwent EPS for primary endpoint assessment. Thirty (24%) patients had CTI re-conduction, distributed with 15 patients in each treatment group (P = 0.62). We observed no difference between treatment groups with regard to fluoroscopy, ablation, or procedure times, nor peri-procedural complications.
Conclusion
Contact force-guided ablation does not reduce re-conduction across the CTI after 3 months, nor does CF-guided ablation shorten fluoroscopy, ablation, or total procedure times.
Publisher
Oxford University Press (OUP)
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献