Randomized study defining the optimum target interlesion distance in ablation index-guided atrial fibrillation ablation

Author:

Hoffmann Philipp1,Diaz Ramirez Ivan1,Baldenhofer Gerd1,Stangl Karl12,Mont Lluís345,Althoff Till F1234ORCID

Affiliation:

1. Department of Cardiology and Angiology, Charité—University Medicine Berlin, Charité Campus Mitte, Charitéplatz 1, 10117 Berlin, Germany

2. DZHK (German Centre for Cardiovascular Research), partner site Berlin, Berlin, Germany

3. Hospital Clínic Atrial Fibrillation Unit (UFA), Arrhythmia Section, Cardiovascular Institute, Hospital Clínic, Universitat de Barcelona, C/Villarroel N° 170, 08036 Barcelona, Catalonia, Spain

4. Institut d’Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Catalonia, Spain

5. Centro de Investigación Biomédica en Red Cardiovascular (CIBERCV), Madrid, Spain

Abstract

Abstract Aims While the CLOSE protocol proposes a maximally tolerable interlesion distance (ILD) of 6 mm for ablation index ablation index-guided atrial fibrillation (AF) ablation, a target ILD has never been defined. This randomized study sought to establish a target ILD for ablation index-guided AF ablation. Methods and results Consecutive patients scheduled for first-time pulmonary vein (PV) isolation (PVI) were randomly assigned to ablation protocols with a target ILD of 5.0–6.0 mm or 3.0–4.0 mm, with the primary endpoint of first-pass PVI. In compliance with the CLOSE protocol, the maximum tolerated ILD was 6.0 mm in both study protocols. A target ablation index of ≥550 (anterior) or ≥400 (posterior) was defined for the ‘5–6 mm’ protocol and ≥500 (anterior) or ≥350 (posterior) for the ‘3–4 mm’ protocol. The study was terminated early for superiority of the ‘3–4 mm’ protocol. Forty-two consecutive patients were randomized and 84 ipsilateral PV pairs encircled according to the study protocol. First-pass PVI was accomplished in 35.0% of the ‘5–6 mm’ group and 90.9% of the ‘3–4 mm’ group (P < 0.0001). Median ILD was 5.2 mm in the ‘5–6 mm’ group and 3.6 mm in the ‘3–4 mm’ group (P < 0.0001). In line with the distinct ablation index targets, median ablation index was lower in the ‘3–4 mm’ group (416 vs. 452, P < 0.0001). While mean procedure time was shorter in the ‘3–4 mm’ group (149 ± 27 vs. 167 ± 33min, P = 0.004), fluoroscopy times did not differ significantly (4.7 ± 2.2 vs. 5.1 ± 1.8 min, P = 0.565). Conclusion In ablation index-guided AF ablation, an ILD of 3.0–4.0 mm should be targeted rather than 5.0–6.0 mm. Moreover, the lower target ILD may allow for less extensive ablation at each given point.

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3