Optimization of anti-tachycardia pacing efficacy through scar-specific delivery and minimization of re-initiation: a virtual study on a cohort of infarcted porcine hearts

Author:

Qian Shuang1ORCID,Connolly Adam2,Mendonca-Costa Caroline1,Campos Fernando1ORCID,Rodero Cristobal1ORCID,Whitaker John13ORCID,Rinaldi Christopher A13ORCID,Bishop Martin J1ORCID

Affiliation:

1. Department of Biomedical Engineering, School of Imaging Sciences and Biomedical Engineering, Kings College London , London , UK

2. Invicro , London , UK

3. Department of Cardiology, Guy’s and St Thomas’ Hospital , London , UK

Abstract

Abstract Aims Anti-tachycardia pacing (ATP) is a reliable electrotherapy to painlessly terminate ventricular tachycardia (VT). However, ATP is often ineffective, particularly for fast VTs. The efficacy may be enhanced by optimized delivery closer to the re-entrant circuit driving the VT. This study aims to compare ATP efficacy for different delivery locations with respect to the re-entrant circuit, and further optimize ATP by minimizing failure through re-initiation. Methods and results Seventy-three sustained VTs were induced in a cohort of seven infarcted porcine ventricular computational models, largely dominated by a single re-entrant pathway. The efficacy of burst ATP delivered from three locations proximal to the re-entrant circuit (septum) and three distal locations (lateral/posterior left ventricle) was compared. Re-initiation episodes were used to develop an algorithm utilizing correlations between successive sensed electrogram morphologies to automatically truncate ATP pulse delivery. Anti-tachycardia pacing was more efficacious at terminating slow compared with fast VTs (65 vs. 46%, P = 0.000039). A separate analysis of slow VTs showed that the efficacy was significantly higher when delivered from distal compared with proximal locations (distal 72%, proximal 59%), being reversed for fast VTs (distal 41%, proximal 51%). Application of our early termination detection algorithm (ETDA) accurately detected VT termination in 79% of re-initiated cases, improving the overall efficacy for proximal delivery with delivery inside the critical isthmus (CI) itself being overall most effective. Conclusion Anti-tachycardia pacing delivery proximal to the re-entrant circuit is more effective at terminating fast VTs, but less so slow VTs, due to frequent re-initiation. Attenuating re-initiation, through ETDA, increases the efficacy of delivery within the CI for all VTs.

Funder

Medical Research Council

NIHR Biomedical Research Centre

NHS Foundation Trust

British Heart Foundation

Welcome EPSRC Centre for Medical Engineering

King’s College London

Welcome Trust

European Union’s Horizon 2020 Research

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference20 articles.

1. Differences in effects of electrical therapy type for ventricular arrhythmias on mortality in implantable cardioverter-defibrillator patients;Sweeney;Heart Rhythm,2010

2. Inappropriate implantable cardioverter-defibrillator shocks: incidence, predictors, and impact on mortality;van Rees;J Am Coll Cardiol,2011

3. Antitachycardia pacing for ventricular tachycardia using implantable cardioverter defibrillators: substrates, methods, and clinical experience;Sweeney;Pacing Clin Electrophysiol,2004

4. Characteristics of the temporal and spatial excitable gap in anisotropic reentrant circuits causing sustained ventricular tachycardia;Peters;Circ Res,1998

5. Basic mechanisms of cardiac impulse propagation and associated arrhythmias;Kléber;Physiol Rev,2004

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3