Feasibility and cardiac synchrony of permanent left bundle branch pacing through the interventricular septum

Author:

Hou Xiaofeng1,Qian Zhiyong1,Wang Yao1,Qiu Yuanhao1,Chen Xing1,Jiang Hai1,Jiang Zeyu1,Wu Hongping1,Zhao Zhongqiang1,Zhou Weihua2,Zou Jiangang1ORCID

Affiliation:

1. Department of Cardiology, The First Affiliated Hospital, Nanjing Medical University, 300 Guangzhou Road, Nanjing, China

2. School of Computing, University of Southern Mississippi, Long Beach, MS, USA

Abstract

Abstract Aims Left bundle branch pacing (LBBP) recently emerges as a novel pacing modality. We aimed to evaluate the feasibility and cardiac synchrony of permanent LBBP in bradycardia patients. Methods and results Left bundle branch pacing was successfully performed in 56 pacemaker-indicated patients with normal cardiac function. Left bundle branch pacing was achieved by penetrating the interventricular septum (IVS) into the left side sub-endocardium with the pacing lead. His-bundle pacing (HBP) was successfully performed in another 29 patients, 19 of whom had right ventricular septal pacing (RVSP) for backup pacing. The QRS duration, left ventricular (LV) activation time (LVAT), and mechanical synchrony using phase analysis of gated SPECT myocardial perfusion imaging were evaluated. Paced QRS duration in LBBP group was significantly shorter than that in RVSP group (117.8 ± 11.0 ms vs. 158.1 ± 11.1 ms, P < 0.0001) and wider than that in HBP group (99.7 ± 15.6 ms, P < 0.0001). Left bundle branch potential was recorded during procedure in 37 patients (67.3%). Left bundle branch pacing patients with potential had shorter LVAT than those without potential (73.1 ± 11.3 ms vs. 83.2 ± 16.8 ms, P = 0.03). Left bundle branch pacing patients with potential had similar LV mechanical synchrony to those in HBP group. R-wave amplitude and capture threshold of LBBP were 17.0 ± 6.7 mV and 0.5 ± 0.1 V, respectively at implant and remained stable during a mean follow-up of 4.5 months without lead-related complications. Conclusion Permanent LBBP through IVS is safe and feasible in bradycardia patients. Left bundle branch pacing could achieve favourable cardiac electrical and LV mechanical synchrony.

Funder

National Natural Science Foundation of China

Science and Technology Department of Jiangsu Province

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 171 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3