Very high-power short-duration ablation for pulmonary vein isolation utilizing a very-close protocol—the FAST AND FURIOUS PVI study

Author:

Heeger Christian-H12ORCID,Sano Makoto13ORCID,Popescu Sorin Ștefan1ORCID,Subin Behnam1ORCID,Feher Marcel1,Phan Huong-Lan1ORCID,Kirstein Bettina1ORCID,Vogler Julia1ORCID,Eitel Charlotte1ORCID,Hatahet Sascha1,Kuck Karl-Heinz14ORCID,Tilz Roland R124ORCID

Affiliation:

1. Department of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein , Ratzeburger Allee 160, Lübeck D-23538 , Germany

2. German Center for Cardiovascular Research (DZHK) , Partner Site Hamburg/Kiel/Lübeck, Lübeck , Germany

3. Division of Cardiology, Internal Medicine III, Hamamatsu University Hospital , 1-20-1 Handayama, Higashi-ku, Hamamatsu city, Shizuoka 431-3192 , Japan

4. LANS Cardio , Stephansplatz 5, Hamburg 20354 , Germany

Abstract

Abstract Aims The very high-power short-duration (vHP-SD) radiofrequency (RF) ablation concept of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective, and faster procedures. Utilizing conventional ablation, the ‘close protocol’ has been verified. Since lesion formation of vHP-SD ablation creates wider but shallower lesions we adapted the close protocol to an individualized and tighter ‘very-close protocol’ of 3–4 mm of inter-lesion distance (ILD) at the anterior and 5–6 mm at the posterior aspect of the left atrium using vHP-SD only. Here, we evaluated the safety and efficacy of vHP-SD ablation for PVI utilizing a very-close protocol in comparison with standard ablation. Methods and results A total of 50 consecutive patients with symptomatic AF were treated with a very-close protocol utilizing vHP-SD (vHP-SD group). The data were compared with 50 consecutive patients treated by the ablation-index-guided strategy (control group). The mean RF time was 352 ± 81 s (vHP-SD) and 1657 ± 570 s (control, P < 0.0001), and the mean procedure duration was 59 ± 13 (vHP-SD) and 101 ± 38 (control, P < 0.0001). The first-pass isolation rate was 74% (vHP-SD) and 76% (control, P = 0.817). Severe adverse events were reported in 1 (2%, vHP-SD) and 3 (6%, control) patients (P = 0.307). A 12-month recurrence-free survival was 78% (vHP-SD) and 64% (control, P = 0.142). PVI durability assessed during redo-procedures was 75% (vHP-SD) vs. 33% (control, P < 0.001). Conclusions PVI solely utilizing vHP-SD via a very-close protocol provides safe and effective procedures with a high rate of first-pass isolations. The procedure duration and ablation time were remarkably low. A 12-month follow-up and PVI durability are promising.

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference20 articles.

1. 2020 ESC guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS): the Task Force for the diagnosis and management of atrial fibrillation of the European Society of Cardiology (ESC) developed with the special contribution of the European Heart Rhythm Association (EHRA) of the ESC;Hindricks;Eur Heart J,2020

2. Cryoballoon or radiofrequency ablation for paroxysmal atrial fibrillation;Kuck;New Engl J Med,2016

3. Prospective use of ablation index targets improves clinical outcomes following ablation for atrial fibrillation;Hussein;J Cardiovasc Electrophysiol,2017

4. Use of ablation index-guided ablation results in high rates of durable pulmonary vein isolation and freedom from arrhythmia in persistent atrial fibrillation patients;Hussein;Circ Arrhythm Electrophysiol,2018

5. Safety and outcome of very high-power short-duration ablation using 70 W for pulmonary vein isolation in patients with paroxysmal atrial fibrillation;Kottmaier;Ep Europace,2019

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3