Epidemiology of cardiac implantable electronic device infections: incidence and risk factors

Author:

Han Hui-Chen1,Hawkins Nathaniel M1,Pearman Charles M12,Birnie David H3,Krahn Andrew D1ORCID

Affiliation:

1. Heart Rhythm Services, Division of Cardiology, Department of Medicine, Center for Cardiovascular Innovation, University of British Columbia, Vancouver, British Columbia, Canada

2. Unit of Cardiac Physiology, Division of Cardiovascular Sciences, Manchester Academic Health Science Centre, Core Technology Facility, University of Manchester, Manchester M13 9XX, UK

3. University of Ottawa Heart Institute, Ottawa, Ontario, Canada

Abstract

Abstract Cardiac implantable electronic device (CIED) infection is a potentially devastating complication of CIED procedures, causing significant morbidity and mortality for patients. Of all CIED complications, infection has the greatest impact on mortality, requirement for re-intervention and additional hospital treatment days. Based on large prospective studies, the infection rate at 12-months after a CIED procedure is approximately 1%. The risk of CIED infection may be related to several factors which should be considered with regards to risk minimization. These include technical factors, patient factors, and periprocedural factors. Technical factors include the number of leads and size of generator, the absolute number of interventions which have been performed for the patient, and the operative approach. Patient factors include various non-modifiable underlying comorbidities and potentially modifiable transient conditions. Procedural factors include both peri-operative and post-operative factors. The contemporary PADIT score, derived from a large cohort of CIED patients, is useful for the prediction of infection risk. In this review, we summarize the key information regarding epidemiology, incidence and risk factors for CIED infection.

Funder

Sauder Family and Heart and Stroke Foundation Chair in Cardiology

Paul Brunes Chair in Heart Rhythm Disorders

Paul Albrechtson Foundation

Medtronic

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 40 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3