Quantitative analysis reveals influencing factors to facilitate successful anodal-ring capture in left bundle branch pacing

Author:

Lu Wenzhao1ORCID,Lin Jinxuan2,Li Yao1,Hu Qingyun1,Cheng Chendi1ORCID,Chen Ruohan1,Dai Yan1,Chen Keping1ORCID,Zhang Shu1ORCID

Affiliation:

1. State Key Laboratory of Cardiovascular Disease, Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences & Peking Union Medical College , No. 167, Beilishi Road, Xicheng District, Beijing 100037 , China

2. Department of Cardiovascular Diseases, The Third Affiliated Hospital of Southern Medical University , Guangzhou , China

Abstract

AbstractAimsLeft bundle branch pacing (LBBP) maintains left ventricular synchrony but induces right ventricular conduction delay (RVCD). Although anodal-ring capture (ARC) during bipolar LBBP improves RVCD, it is not achieved in all patients receiving LBBP. This study aimed to analyze the factors influencing ARC implementation.Methods and resultsPatients receiving LBBP with intraoperative ARC testing were enrolled. Electrocardiographic parameters were measured, including stimulus-to-QRS duration (stim-QRSd), stimulus-to-left/right ventricular activation time (stim-LVAT/RVAT), and V6-V1 interpeak interval. The distribution of lead-tip sites was described as the corrected longitudinal and lateral distance (longit-/lat-dist). Relative angles of the LBBP lead were measured. Echocardiography in short-axis view was used to measure the intraseptal lead length. Intergroup comparisons, correlation analysis, and stepwise logistic regression were performed. In total, 105 patients were included, among which 65 (62%) patients achieved ARC at a pacing output ≤ 5.0 V/0.5 ms (average 3.1 V/0.5 ms). Anodal-ring capture further shortened the stim-QRSd by 13.1 ± 7.5 ms. Better unipolar-ring (cathodal) threshold and R-wave sensing in LBBP-ARC group indicated the critical role of ring–septum contact in ARC. Longer corrected longit-dist and shorter corrected lat-dist of lead-tip sites were positively correlated with higher success likelihood of ARC, likely due to the greater relative angle in which the lead enters the septum and consequently the longer intraseptal lead length and better ring–septum contact.ConclusionThis study elucidated the factors affecting the success likelihood of LBBP-ARC. These findings improve the understanding of LBBP-ARC, providing references for future research and clinical practice.

Funder

National Natural Science Foundation of China

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3