Performance and safety of temperature- and flow-controlled radiofrequency ablation for ventricular arrhythmia

Author:

Kobza Richard1ORCID,Hilfiker Gabriela1,Rissotto Sophie2ORCID,Mahida Saagar3,Grebmer Christian1ORCID,Duru Firat4ORCID,Pürerfellner Helmut5ORCID,Berte Benjamin1ORCID

Affiliation:

1. Heart Center, Luzerner Kantonsspital , Zentralstrasse 1 , Lucerne 6004, Switzerland

2. Clinical Support, Biosense Webster , Zug , Switzerland

3. Department of Cardiac Electrophysiology, Liverpool Heart and Chest Hospital , Liverpool , UK

4. Cardiology Department, University Hospital Zürich , Zürich , Switzerland

5. Department of Cardiology, Ordensklinikum Linz Elisabethinen , Linz , Austria

Abstract

Abstract Aims High-power ablation is effective for ventricular arrhythmia ablation; however, it increases the risk of steam pops. The aim of this study was to define the safety and efficacy of QMODE ablation in the ventricle and the risk of steam pop. Methods and results Consecutive patients undergoing ventricular ablation using QDOT were included in a prospective single-centre registry. Procedural data, complications, and follow-up were systematically analysed and compared with a historical ventricular tachycardia (VT) and premature ventricular complexes (PVC) cohort ablated using STSF. QMODE (≤50 W) ablation was performed in 107 patients [age 62 ± 13 years; 76% male; VT (n = 41); PVC (n = 66)]. A total of 2456 applications were analysed [power: 45.9 ± 5.0 W with minimal power titration (90% > 95% max power); duration 26 ± 8 s; impedance drop 9.4 ± 4.7 Ω; ablation index: 569 ± 163; mean–max temperature 44.3 ± 2.6°C]. Ventricular tachycardia ablation was associated with shorter radiofrequency (RF) time and a trend towards shorter procedure times using QDOT (QDOT vs. STSF: 20.1 ± 14.7 vs. 31 ± 17 min; P = 0.002, 151 ± 59 vs. 172 ± 48 min; P = 0.06). Complications, VT recurrence, and mortality rates were comparable (QDOT vs. STSF: 2% vs. 2%; P = 0.9, 24% vs. 27%; P = 0.82, and 2% vs. 4%; P = 0.67). Five audible steam pops (0.02%) occurred. Premature ventricular complex ablation was associated with comparable RF and procedure times (QDOT vs. STSF: 4.8 ± 4.6 vs. 3.9 ± 3.1 min; P = 0.25 and 96.1 ± 31.9 vs. 94.6 ± 24.7 min; P = 0.75). Complication and PVC recurrence were also comparable (QDOT vs. STSF: 0% vs. 3%; P = 0.17 and 19% vs. 22%; P = 0.71). Conclusion Ventricular ablation using QMODE ≤ 50 W is safe and effective for both VT and PVC ablation and is associated with a low risk for steam pop.

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司