Magnetic resonance imaging in patients with temporary external pacemakers

Author:

Fyenbo Daniel Benjamin12ORCID,Jensen Morten Steen Kvistholm12,Kronborg Mads Brix12,Kristensen Jens1ORCID,Nielsen Jens Cosedis12ORCID,Witt Christoffer Tobias1ORCID

Affiliation:

1. Department of Cardiology, Aarhus University Hospital , 8200 Aarhus N , Denmark

2. Department of Clinical Medicine, Aarhus University , 8200 Aarhus N , Denmark

Abstract

Abstract Aims To describe safety and feasibility of magnetic resonance imaging (MRI) in patients with transvenous temporary external pacemakers and whether artefacts affect the diagnostic image quality during cardiac MRI. Methods and results We reviewed records of all patients treated with temporary external pacing between 2016 and 2020 at a tertiary centre. Temporary pacing was established using a transvenous standard active fixation pacing lead inserted percutaneously and connected to a MRI-conditional pacemaker taped to the skin. All patients undergoing cardiac or non-cardiac MRI during temporary transvenous pacing were identified. Before MRI, devices were programmed according to guidelines for permanent pacemakers, and patients were monitored with continuous electrocardiogram during MRI. Of 827 consecutive patients receiving a temporary external pacemaker, a total of 44 (5%) patients underwent MRI (mean age 71 years, 13 [30%] females). Cardiac MRI was performed in 22 (50%) patients, while MRI of cerebrum, spine, and other regions was performed in the remaining patients. Median time from implantation of the temporary device to MRI was 6 (3–11) days. During MRI, we observed no device-related malfunction or arrhythmia. Nor did we detect any change in lead sensing, impedance, or pacing threshold. We observed no artefacts from the lead or pacemaker compromising the diagnostic image quality of cardiac MRI. MRI provided information to guide the clinical management in all cases. Conclusion MRI is feasible and safe in patients with temporary external pacing established with a regular MRI-conditional pacemaker and a standard active fixation lead. No artefacts compromised the diagnostic image quality.

Funder

Aarhus University

Danish Heart Foundation

Health Research Foundation of Central Denmark Region

Gangstedfonden; and Karen Elise Jensens Foundation

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Interventional cardiovascular magnetic resonance: state-of-the-art;Journal of Cardiovascular Magnetic Resonance;2023-08-14

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3