Delayed detection programming significantly reduces inappropriate ICD therapies in patients with left-ventricular assist devices

Author:

Hohmann S1,Heimeshoff J2,Mueller-Leisse J1,Hillmann H1,Eiringhaus J1,Zormpas C1,Koenig T1,Schmitto J2,Bauersachs J1,Veltmann C1,Duncker D1

Affiliation:

1. Hannover Medical School, Department of Cardiology and Angiology, Hannover Heart Rhythm Center, Hannover, Germany

2. Hannover Medical School, Department of Cardiothoracic Surgery, Hannover, Germany

Abstract

Abstract Funding Acknowledgements Type of funding sources: None. Background Implantation of a left ventricular assist device (LVAD) is an established therapy for end-stage heart failure, either as bridge to transplantation or as destination therapy. Virtually all LVAD patients carry an implantable cardioverter-defibrillator (ICD) for primary or secondary prevention. The risk of ventricular tachyarrhythmias is significant in LVAD patients, but so is the burden of supraventricular tachycardia and the ensuing risk of inappropriate ICD therapies. The present retrospective study sought to quantify the impact of standard ICD programming vs. a ICD programming with long detection delays on the occurrence of inappropriate ICD therapies. Methods and results We retrospectively identified 337 consecutive patients (292 male, mean age 54.2 ± 12.3 years) who received a continuous-flow LVAD at our institution. Median follow-up duration was 2.3 (IQR 1.3, 3.7) years. Heart failure etiology was ischemic cardiomyopathy in 155 patients (46.0 %) and non-ischemic dilated cardiomyopathy in 150 (44.5 %). Other etiologies accounted for 32 patients (9.4 %). ICDs implanted at the time of LVAD implantation were single chamber devices in 176 patients (52.2 %), dual chamber devices in 45 patients (13.4 %), and CRT-D in 116 patients (34.4 %) A total of 2228 ICD-treated arrhythmia episodes occurred in 153 patients. 2066 (92.6 %) episodes were appropriate interventions for ventricular arrhythmias. 162 (7.3 %) treatments were inappropriate due to supraventricular tachyarrhythmias (n=115; 71.4 %), sinus tachycardia (n=15; 9.3 %) or oversensing (n=21; 12.9%). We retrospectively compared a standard programming (number of intervals for detection [NID] in the slowest therapy zone ≤ 40) and a long delay programming (NID > 40) and investigated the time to the first inappropriate therapy. A total of 285 patients were programmed to NID ≤ 40 at the first ICD interrogation after LVAD implant, 47 were programmed to NID > 40. Therapies were inactive in the remaining 5 patients. Median NID was 30 (IQR 23, 35) in the standard programming group and 60 (IQR 50, 76) in the long delay group, with similar rates for detection (median cycle lengths 340 [IQR 330, 350] ms and 330 [IQR 322, 340] ms for standard and long delay, respectively). Long delay programming was associated with significantly higher freedom from inappropriate therapies during follow-up (Hazard ratio 0.14, p [log rank] 0.027). No significant difference was observed between groups with regard to time to first appropriate therapy. Conclusion A number of intervals for detection greater than 40 in the slowest therapy zone was associated with a significantly increased freedom from inappropriate therapies in this large retrospective single-center cohort of LVAD patients with an ICD and should be considered as the default ICD programming strategy in this population.

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3