A METHOD TO IDENTIFY AND LOCALIZE A SINGLE HOT PARTICLE IN THE LUNGS USING AN ARRAY OF HIGH-PURITY GERMANIUM DETECTORS FOR IMPROVED ESTIMATE OF THE DEPOSITED ACTIVITY

Author:

Aviv O1ORCID,Epstein L1,Fried Y1,Spitz H B2,Shonkor S1,Epstein D3,Naim A1,Yungrais Z1,Datz H1

Affiliation:

1. Radiation Safety Department, Soreq Nuclear Research Center, Yavne 81800, Israel

2. Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, OH 45221-0072, USA

3. Department of Radiotherapy, Assuta Medical Center, Tel Aviv 6971028, Israel

Abstract

Abstract A new method has been developed to identify and localize a single hot particle in the lungs using an array of four high-purity germanium detectors. The method is based upon calculating a set of three count rate ratios (generated by each individual detector in the array) that are evaluated in sequence to designate whether the measured deposition can be associated with a hot particle rather than the default assumption of a uniform activity distribution. Identification and localization of the hot particle are determined from a single in vivo measurement in which detectors are positioned above and below the thorax. The method was tested using an anthropomorphic thorax phantom in which point sources of 241Am, 137Cs and 60Co were individually inserted in the lungs at 15 different locations and were measured using a scanning bed whole-body counter. Depending upon source location and photon energy, a bias of −35% up to +76% could be introduced by falsely assuming a uniform activity distribution in the lungs. This bias would directly translate to an erroneous dose estimate to the lungs. It was demonstrated that by using the appropriate detector efficiencies for the single hot particle, the bias associated with the activity determination is reduced to <10% and ~2% in average.

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Reference18 articles.

1. Individual monitoring for internal exposure of workers. ICRP report 78;International Commission on Radiological Protection (ICRP);Ann. ICRP,1998

2. Human respiratory tract model for radiological protection. ICRP report 66;International Commission on Radiological Protection (ICRP);Ann. ICRP,1994

3. Use of bioassay procedures for assessment of internal radionuclide deposition;National Council on Radiation Protection and Measurements (NCRP),1987

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3