Affiliation:
1. Department of Medical Diagnostic Imaging, College of Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates
Abstract
Abstract
Electronic image cropping and poor collimation practices are used by some radiographers during paediatric radiography. Advantages of collimation should be investigated to disseminate convenient use among radiographers and create awareness. The aim of this study was to use Monte Carlo simulation to investigate the extent of the effect of collimation on the absorbed organ dose in neonates undergoing anterior–posterior chest examination. The minimum field size recommended by the European guidelines was calculated experimentally using a neonate phantom. A PCXMC version 2.0 simulation calculated the organ and effective doses at the minimum field size and at different field sizes. Increasing the field size by 1 cm in the head-to-feet direction increases the dose to the urinary bladder and prostate, whereas increasing the field size by 1 cm on all sides increases the dose to the upper limbs, ovaries, testicles and prostate. The use of an optimal field size reduces organ doses for neonates undergoing chest X-ray. Cropping X-ray images to reduce unnecessarily large field sizes results in unnecessary patient dosages and should be avoided. The primary beam should be restricted to expose only the area of interest, and image cropping should be discouraged.
Publisher
Oxford University Press (OUP)
Subject
Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献